NI CVS-1459RT Getting Started Guide

|

© National Instruments

|

15

Worldwide Support and Services

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development 

self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and 

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration 

facilitates technical support and ensures that you receive important information updates from NI. 

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European 
Communities using the manufacturer’s declaration of conformity. This system affords the user 
protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC 
for your product by visiting 

ni.com/certification

. If your product supports calibration, 

you can obtain the calibration certificate for your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 
Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For 
telephone support in the United States, create your service request at 

ni.com/support

 or dial 

1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the 
Worldwide Offices section of 

ni.com/niglobal

 to access the branch office websites, which 

provide up-to-date contact information, support phone numbers, email addresses, and current 
events.

Summary of Contents for CVS-1459RT

Page 1: ...ling the Vision Development Module 5 Configuring the Hardware 6 Wiring Power to the NI CVS 1459RT 8 Connecting the System Power Supply 8 Connecting the Isolated Outputs Power Supply 8 Connecting USB3...

Page 2: ...resulting in degraded network performance Development computer running Microsoft Windows Refer to the driver or application development software readme for specific Windows version compatibility A co...

Page 3: ...ty of the NI CVS 1459RT in LabVIEW or to reconfigure the default personality of the NI CVS 1459RT I O in the LabVIEW FPGA Module Safety Information Caution The following paragraphs contain important s...

Page 4: ...which the device is rated Do not exceed the maximum ratings for the device Remove power from signal lines before connection to or disconnection from the device Electromagnetic Compatibility Guideline...

Page 5: ...e to develop applications and LabVIEW FPGA to reconfigure the I O The software must be installed in this order 1 LabVIEW Refer to the LabVIEW Installation Guide for installation instructions and syste...

Page 6: ...equirements and installation instructions for the NI IMAQ I O driver Documentation for the NI IMAQ I O driver software is available by selecting Start All Programs National Instruments Vision Document...

Page 7: ...2 System Power Connector 3 Isolated Outputs Power Connector 4 Chassis Grounding Screw 1 VGA Connector 2 RJ50 Serial Port 3 USB 2 0 Ports 4 RJ45 Network Port 5 USB3 Vision Ports 6 44 pin Digital I O Co...

Page 8: ...N m 1 8 to 2 2 lb in of torque 4 Connect the negative lead of the power source to the C terminal of the power connector plug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torq...

Page 9: ...onnect to the development computer directly or through a network To connect over a network the device must be on the same subnet as the development computer Direct Connection Complete the following st...

Page 10: ...ble targets 3 Select the Configure Target icon 4 Complete the configuration wizard At step 3 select Update Target Software to install Vision Builder AI on the device Configuring the Device in NI MAX C...

Page 11: ...of available targets 3 In the Configure Inspection section select New Inspection from Template 4 Select Acquire Image Template from the Compact Vision System tree 5 Click the Run Inspection Once icon...

Page 12: ...TTL 1 Bidirectional TTL I O 5 GND Digital ground reference for TTL and differential I O 6 TTL 2 Bidirectional TTL I O 7 TTL 3 Bidirectional TTL I O 8 GND Digital ground reference for TTL and differen...

Page 13: ...ral purpose isolated input 33 CISO Common ground reference for isolated inputs and outputs 34 Iso In 2 General purpose isolated input 35 Iso In 3 General purpose isolated input 36 CISO Common ground r...

Page 14: ...n Builder AI inspections are installed to the Vision Builder AI Examples directory where Vision Builder AI is the location Vision Builder AI is installed Additional Resources for LabVIEW Users Documen...

Page 15: ...ncil of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the...

Page 16: ...s You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal expor...

Reviews: