Chapter 2
Analog Input Timing/Control
©
National Instruments Corporation
2-103
DAQ-STC Technical Reference Manual
2.7.8.3 SCAN_IN_PROG Deassertion
You can output SCAN_IN_PROG on the SCAN_IN_PROG pin, PFI7/AI_START, or the
RTSI_BRD<2..3> outputs. If AI_External_Mux_Present is 0, SCAN_IN_PROG deasserts on
the SOC edge that occurs while STOP is asserted. If AI_External_Mux_Present is 1,
SCAN_IN_PROG deasserts on the SOC edge that occurs while STOP and DIV_TC are both
asserted. Figure 2-35 shows the behavior of the SCAN_IN_PROG outputs during
deassertion.
Figure 2-35.
SCAN_IN_PROG Deassertion
2.7.8.4 STOP Trigger
You can output the STOP trigger on the dedicated output AI_STOP_OUT or on the
RTSI_BRD<0..1> pins. The timing for STOP depends on whether you select synchronous
mode or asynchronous mode, using AI_STOP_Sync.
Name
Description
Minimum
Maximum
Tscan
SOC to SCAN_IN_PROG
8
26
Tpfi
SOC to PFI output
8
27
Tsbrd
SOC to BRD output
9
31
All timing values are in nanoseconds.
STOP
SOC
SCAN_IN_PROG
PFI7/AI_START
Tpfi
RTSI_BRD<2..3>
Tscan
Tsbrd