AI_DIV_Load_A_Register
Address: 64
Type: Write-only
15
AI_DIV_Load_A
14
AI_DIV_Load_A
13
AI_DIV_Load_A
12
AI_DIV_Load_A
11
AI_DIV_Load_A
10
AI_DIV_Load_A
9
AI_DIV_Load_A
8
AI_DIV_Load_A
7
AI_DIV_Load_A
6
AI_DIV_Load_A
5
AI_DIV_Load_A
4
AI_DIV_Load_A
3
AI_DIV_Load_A
2
AI_DIV_Load_A
1
AI_DIV_Load_A
0
AI_DIV_Load_A
AI_Mode_1_Register
Address: 12
Type: Write-only
15
AI_CONVERT_Source_Select
14
AI_CONVERT_Source_Select
13
AI_CONVERT_Source_Select
12
AI_CONVERT_Source_Select
11
AI_CONVERT_Source_Select
10
AI_SI_Source_Select
9
AI_SI_Source_Select
8
AI_SI_Source_Select
7
AI_SI_Source_Select
6
AI_SI_Source_Select
5
AI_CONVERT_Source_Polarity
4
AI_SI_Source_Polarity
3
AI_Start_Stop
2
Reserved_One
1
AI_Continuous
0
AI_Trigger_Once
AI_DIV_Save_Register
Address: 26
Type: Read-only
15
AI_DIV_Save_Value
14
AI_DIV_Save_Value
13
AI_DIV_Save_Value
12
AI_DIV_Save_Value
11
AI_DIV_Save_Value
10
AI_DIV_Save_Value
9
AI_DIV_Save_Value
8
AI_DIV_Save_Value
7
AI_DIV_Save_Value
6
AI_DIV_Save_Value
5
AI_DIV_Save_Value
4
AI_DIV_Save_Value
3
AI_DIV_Save_Value
2
AI_DIV_Save_Value
1
AI_DIV_Save_Value
0
AI_DIV_Save_Value
AI_Mode_2_Register
Address: 13
Type: Write-only
15
AI_SC_Gate_Enable
14
AI_Start_Stop_Gate_Enable
13
AI_Pre_Trigger
12
AI_External_MUX_Present
11
Reserved
10
Reserved
9
AI_SI2_Initial_Load_Source
8
AI_SI2_Reload_Mode
7
AI_SI_Initial_Load_Source
6
AI_SI_Reload_Mode
5
AI_SI_Reload_Mode
4
AI_SI_Reload_Mode
3
AI_SI_Write_Switch
2
AI_SC_Initial_Load_Source
1
AI_SC_Reload_Mode
0
AI_SC_Write_Switch