Table 4. ECUTS-16001 Optional Hardware Components (Continued)
Component Type
Maximum Quantity
Part
Description
Power Supplies
8 total
RMX-4101, 20 V
20 V, 10 A, programmable power supply device
RMX-4101, 36 V
36 V, 6 A, programmable power supply device
RMX-4101, 60 V
60 V, 3.5 A, programmable power supply device
RMX-4102, 20 V
20 V, 20 A, programmable power supply device
RMX-4102, 36 V
36 V, 12 A, programmable power supply device
RMX-4102, 60 V
60 V, 7 A, programmable power supply device
RMX-4104, 20 V
20 V, 40 A programmable power supply device
RMX-4104, 36 V
36 V, 24 A programmable power supply device
RMX-4104, 60 V
60 V, 14 A programmable power supply device
Peripheral Components
1
USB hub
7-Port USB 2.0 hub
1
FDT-16041
Field diagnostic tester for ECU Test System
PXI
The PXI instrumentation in the ECUTS includes a PXI Chassis, a PXIe-8861 Controller, and user-configured PXI modular instruments.
Programmable Power Supplies
The ECUTS includes up to eight rack-mount RMX-410x programmable power supplies. Power supplies can be powered by a secondary PDU.
The following figure displays the IP address assigned to each power supply according to its location in the test rack.
Figure 1. Power Supply IP Address Assignments
169.254.160.22
169.254.160.23
169.254.160.26
169.254.160.27
169.254.160.25
169.254.160.21
169.254.160.28
169.254.160.24
(ECUTS-16000) Rack Mount Electronic Loads
The ECUTS-16000 includes one electronic load mainframe and up to four RMX-4003 or RMX-4005 electronic load devices.
The IP address assigned to the electronic load instrumentation is 169.254.160.30.
Power Distribution Unit
The ECUTS-16000 contains one power distribution unit (PDU) that takes input power and distributes AC and DC power to the ECUTS-16000
components.
The ECUTS-16001 contains two PDUs. One PDU takes input power and distributes AC and DC power to the ECUTS-16001 components, and
the second PDU takes power and distributes AC power to the ECUTS-16001 components.
Both ECUTS models use a single-phase PDU that supports global voltages (200 V to 240 V; 50 Hz to 60 Hz) and has a 20 A (IEC C19) input
connector that cables directly to the PEP. The eight standard AC sockets on the PDU are allocated in a specific configuration to power the
internal components of the ECUTS and balance the power loads.
SLSC
The load-switching instrumentation in the ECUTS includes up to twelve switch load signal conditioning (SLSC) fault insertion units (FIU) that
provide high-current switching and current measurement. Refer to the SLSC-12251 and SLSC-12252 User Manual to learn more about SLSC
capabilities, including routing information and supported signal bandwidth.
The ECUTS supports the following:
•
Up to twelve SLSC-12251 5 A fault insertion units
•
Up to six SLSC-12251 8 A fault insertion units
•
Up to three SLSC-12252 30 A fault insertion units
6
|