FieldPoint
™
Operating Instructions
FP-AI-100 and cFP-AI-100
Eight-Channel, 12-Bit Analog Input Modules
These operating instructions describe how to install and use the
FP-AI-100 and cFP-AI-100 analog input modules (referred to
inclusively as the [c]FP-AI-100). For information about
configuring and accessing the [c]FP-AI-100 over a network,
refer to the user manual for the FieldPoint network module you are
using.
Features
The [c]FP-AI-100 is a FieldPoint analog input module with the
following features:
•
Eight analog voltage or current input channels
•
11 input ranges: 0–1 V, 0–5 V, 0–15 V, 0–30 V,
±
1 V,
±
5 V,
±
15 V,
±
30 V, 0–20 mA, 4–20 mA, and
±
20 mA
•
12-bit resolution
•
250 V
rms
CAT II continuous channel-to-ground isolation,
verified by 2,300 V
rms
,1 minute dielectric withstand test
•
–40 to 70 °C operation
•
Hot swappable
Installing the FP-AI-100
The FP-AI-100 mounts on a FieldPoint terminal base (FP-TB-
x
),
which provides operating power to the module. Installing the
FP-AI-100 onto a powered terminal base does not disrupt the
operation of the FieldPoint bank.