background image

Installing NI-IMAQdx

Before using the ISC-178x in environments other than Vision Builder AI, install the necessary
drivers onto the device and the Windows development machine. Complete the following steps
to install and configure NI-IMAQdx:
1.

Install NI-IMAQdx 16.2 or later onto the Windows development machine connected to
the ISC-178x. NI-IMAQdx is included on the NI Vision Acquisition Software DVD. You
can also download NI Vision Acquisition Software from 

ni.com/support

.

2.

Run NI MAX.

3.

Expand the 

Remote Systems

 list in the configuration tree.

4.

Select the ISC-178x in the list. By default, MAX lists devices by the model number
followed by the serial number, such as NI-ISC-178x-XXXXXXXX.

5.

Configure the network settings for the ISC-178x. Refer to the 

Remote Systems Help

 in

MAX. Select 

Help

»

Help Topics

»

Remote Systems

 for instructions about configuring

network settings.

6.

Install a recommended software set. If you would like to install custom software instead
of a recommended software set, proceed to the next step.
a)

Expand the ISC-178x under 

Remote Systems

.

b)

Click the 

Software

 item below the ISC-178x in the configuration tree.

c)

Click 

Add/Remove Software

 on the MAX toolbar to launch the LabVIEW Real-

Time Software Wizard.

d)

Enter 

admin

 as the username and leave the password field blank.

e)

Select Vision Software under the version of LabVIEW Real-Time you are using.

f)

Click 

Next

.

g)

Select any additional add-ons you would like to install to the ISC-178x.

h)

Click 

Next

. Review the list of software to install.

i)

Click 

Next

 to begin downloading the software to the ISC-178x. When MAX finishes

downloading the software, the ISC-178x restarts.

j)

Click 

Finish

.

7.

Install custom software. You do not need to install custom software if you installed a
recommended software set.
a)

Expand the ISC-178x under 

Remote Systems

.

b)

Click the 

Software

 item below the ISC-178x in the configuration tree.

c)

Click 

Add/Remove Software

 on the NI MAX toolbar to launch the LabVIEW Real-

Time Software Wizard.

d)

Enter 

admin

 as the username and leave the password field blank.

e)

Choose 

Custom software installation

 and click 

Next

 to proceed with a custom

installation.

f)

Select NI-IMAQdx, and any additional software you would like to install on the
ISC-178x.

g)

Click 

Next

. Review the list of software to install.

h)

Click 

Next

 to begin downloading the software to the ISC-178x. When NI MAX

finishes downloading the software, the ISC-178x restarts.

ISC-178x Getting Started Guide

  | 

© National Instruments

  | 

9

Summary of Contents for ISC-178 Series

Page 1: ...uctions and cautions in the user documentation Using the ISC 178x in a manner not specified can damage the model and compromise the built in safety protection Return damaged models to NI for repair Caution The case of the ISC 178x can become hot and should not be touched while operating Always allow hot surfaces to cool before touching the ISC 178x Caution The ISC 178x must be mounted to a support...

Page 2: ...ent Operate the device only at or below the pollution degree stated in the specifications Pollution consists of any foreign matter solid liquid or gas that may reduce dielectric strength or surface resistivity The following is a description of pollution degrees Pollution Degree 1 No pollution or only dry nonconductive pollution occurs The pollution has no effect Pollution Degree 2 Normally only no...

Page 3: ...ter Kit for ISC 178x Smart Cameras NI part number 785830 02 X Code M12 to RJ45 Network Cable 5 m NI part number 145230A 05 A Code M12 to A Code M12 Power and I O Cable 3 m NI part number 145232A 03 M12 to VGA USB Splitter Cable 1 m NI part number 782022 01 Power and I O Accessory for ISC 178x Smart Camera NI part number 145227A 01 Power Supply PS 10 100 VAC to 240 VAC 24 VDC 5A NI part number 7826...

Page 4: ...mage sensor 3 C mount lens mount 4 Varioptic liquid lens connector Figure 2 ISC 178x Connectors Power Status User 100 1G 1 2 3 4 1 LED indicators 2 Power and I O connector 3 VGA and USB connector 4 Network connector 4 ni com ISC 178x Getting Started Guide ...

Page 5: ... for isolated inputs 7 Iso In 2 General purpose isolated input 8 Iso In 3 NI Linux Real Time Reserved for safe mode Windows General purpose isolated input 9 Iso In 1 General purpose isolated input 10 Iso Out 0 General purpose isolated output positive 11 C System power and analog reference common 12 Iso Out 1 General purpose isolated output positive The following NI power and I O cables are availab...

Page 6: ...Power and I O Accessory for ISC 178x Smart Cameras User Manual for more information 1 Verify the power source is turned off 2 Connect and secure the M12 connector of the terminal block cable to the Power and I O connector on the smart camera 3 Connect and secure the other end of the terminal block cable to the terminal block 4 Connect any additional I O signals necessary for your application to th...

Page 7: ... liquid lens connector on the ISC 178x Once the connector is in place use the tweezers to press firmly on either side of the wires to ensure a good connection 8 Slide the lens cover over the lens and screw it into the ISC 178x housing until it is firmly in place The lens cover must be in place for IP67 conformity 9 Reconnect the power to the ISC 178x When the ISC 178x powers on with a compatible l...

Page 8: ...network 1 Verify the development computer is powered on and connected to the network 2 Connect one end of an M12 Ethernet cable to the network connector on the ISC 178x 3 Connect the free end of the Ethernet cable to an Ethernet switch or network device 4 Verify the 100 1G LED on the smart camera is on or blinking The device negotiates an IP address when connected to a network with a DHCP server o...

Page 9: ... c Click Add Remove Software on the MAX toolbar to launch the LabVIEW Real Time Software Wizard d Enter admin as the username and leave the password field blank e Select Vision Software under the version of LabVIEW Real Time you are using f Click Next g Select any additional add ons you would like to install to the ISC 178x h Click Next Review the list of software to install i Click Next to begin ...

Page 10: ...ra is on or blinking Note By default the operating system automatically attempts to connect to the network using DHCP If it is unable to initiate a DHCP connection it connects to the network with a link local IP address 169 254 x x Installing NI IMAQdx Driver Software Before using the ISC 178x install other National Instruments software such as application development environments and then install...

Page 11: ...th the ISC 178x and the development computer are properly connected to the network The Power LED should be lit green the Status LED should be lit orange or green and the 100 1G LED should flash green when refreshing the list of devices in MAX Ensure you are connecting to the ISC 178x from a Windows development computer with NI IMAQdx installed The ISC 178x may have been configured on another netwo...

Page 12: ...DP Ports Used by the ISC 178x Port Type Details 3580 TCP UDP Reserved as nati svrloc NATI ServiceLocator Used by MAX to locate remote targets 7749 TCP Used for remote image display not reserved 7750 TCP Used for NI IMAQdx remote configuration not reserved 3363 TCP UDP Reserved as nati vi server NATI VI Server Used by Vision Builder AI to configure a remote target If your firewall is controlled rem...

Page 13: ...ate Limit attribute Related Information Installing NI IMAQdx on page 9 LED Indications The ISC 178x indicates specific error conditions by flashing the Power Status and User LEDs Table 4 LED Indications Power LED Status LED User LED Indication Off Off Off The ISC 178x does not have power Red Red Red The ISC 178x is powered but is not responding Red Orange Initialization error Orange Orange Red bli...

Page 14: ...he Power and I O Accessory for ISC 178x Smart Cameras ISC 178x User Manual Contains detailed electrical and mechanical information about the ISC 178x ISC 1780 Specifications Contains detailed specifications for the ISC 1780 ISC 1781 Specifications Contains detailed specifications for the ISC 1781 ISC 1782 Specifications Contains detailed specifications for the ISC 1782 ISC 1783 Specifications Cont...

Page 15: ...For support in the United States create your service request at ni com support or dial 1 866 ASK MYNI 275 6964 For support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information ISC 178x Getting Started Guide National Instruments 15 ...

Page 16: ...nts EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY E...

Reviews: