LFH200 Cable Installation Instructions
34
ni.com
Specifications
The following specifications list properties of the multi-conductor cable used to fabricate the
LFH200 cable.
Maximum voltage .............................................60 VDC, CAT I
Impedance
Differential ................................................100 ±15
Ω
Single-ended .............................................65 ±15
Ω
Capacitance
Mutual .......................................................15.0 pF/ft nominal
Single-ended .............................................25.0 pF/ft nominal
Time delay.........................................................1.60 ns/ft maximum
Time delay skew ...............................................0.040 ns/ft maximum
Attenuation
Differential ................................................0.025 dB/ft maximum at 5 MHz
Single-ended .............................................0.085 dB/ft maximum at 50 MHz
Conductor DC resistance ..................................0.070
Ω
/ft maximum at 20 °C
Gauge ................................................................28 AWG