background image

©

 National Instruments Corporation

5

Getting Started with the NI 7811R

Installation

You can install the PXI-7811R in any available peripheral slot in the PXI 
or CompactPCI chassis. Complete the following steps to install the 
PXI-7811R device.

Note

You must install the software before installing the hardware. For software 

installation instructions, refer to the 

Installing Software

 

section.

1.

Power off and unplug the PXI or CompactPCI chassis.

2.

Make sure there are no lit LEDs on the chassis. Wait for any lit LEDs 
to go out before continuing the installation.

3.

Remove the filler panel for the peripheral slot.

4.

Ground yourself using a grounding strap or by touching a grounded 
object, such as the PXI or CompactPCI chassis. 

5.

Insert the PXI-7811R into the slot. Use the injector/ejector handle to 
fully inject the PXI-7811R into place.

6.

Screw the front panel of the PXI-7811R to the front panel mounting 
rails of the chassis.

7.

Visually verify the installation. Make sure the PXI-7811R is not 
touching other devices or components and that the PXI-7811R is 
fully inserted into the slot.

8.

Plug in and power on the PXI or CompactPCI chassis.

Connecting Signals

The PXI-7811R has four DIO connectors with 40 DIO lines per DIO 
connector.

Figure 1 shows the I/O connector locations for the PXI-7811R. The 
I/O connectors are numbered starting at zero. 

Summary of Contents for Network Device NI PXI-7811R

Page 1: ...learn a low level programming language or a hardware description language HDL traditionally used for FPGA design With the LabVIEW FPGA Module you create or download a custom virtual instrument VI to...

Page 2: ...tems to set up and use the PXI 7811R with Windows 2000 XP PXI 7811R device The following software packages LabVIEW 7 1 or later LabVIEW FPGA Module 1 1 or later required to develop custom FPGA VIs for...

Page 3: ...and LabVIEW Installing LabVIEW the LabVIEW Real Time Module for ETS and the LabVIEW FPGA Module Use the following sequence when installing LabVIEW the LabVIEW Real Time Module for ETS and the LabVIEW...

Page 4: ...ction describes how to unpack and install the PXI 7811R device You can install the PXI 7811R in any available peripheral slot in the PXI or CompactPCI chassis Note You must install the NI RIO device d...

Page 5: ...e filler panel for the peripheral slot 4 Ground yourself using a grounding strap or by touching a grounded object such as the PXI or CompactPCI chassis 5 Insert the PXI 7811R into the slot Use the inj...

Page 6: ...Getting Started with the NI 7811R 6 ni com Figure 1 PXI 7811R Connector Locations CONNECTOR 0 DIO CONNECTOR 1 DIO CONNECTOR 3 DIO CONNECTOR 2 DIO Reconfigurable I O NI PXI 7811R...

Page 7: ...anual Cabling Options Accessing the signals on the I O connectors requires at least one cable and one signal accessory Table 1 summarizes the National Instruments cables available for use with the NI...

Page 8: ...cations in LabVIEW with the LabVIEW FPGA Module PXI 7811R User Manual describes the electrical and mechanical aspects of the PXI 7811R device and contains information concerning its operation and prog...

Reviews: