32
|
ni.com
|
NI 5782R User Manual and Specifications
Environmental
Operating environment
1
....................................0 °C to 55 °C,
tested in accordance with IEC-60068-2-1 and
IEC-60068-2-2.
Relative humidity range....................................10% to 90%, noncondensing,
tested in accordance with IEC-60068-2-56.
Maximum altitude.............................................2,000 m at 25 °C ambient temperature.
Pollution Degree ...............................................2
Indoor use only.
Storage environment
Ambient temperature range ......................-20 °C to 70 °C,
tested in accordance with IEC-60068-2-1 and
IEC-60068-2-2.
Relative humidity range............................5% to 95%, noncondensing,
tested in accordance with IEC-60068-2-56.
Note
Clean the device with a soft, non-metallic brush. Make sure that the device is
completely dry and free from contaminants before returning it to service.
Shock and Vibration
Operational shock .............................................30 g peak, half-sine, 11 ms pulse,
tested in accordance with IEC-60068-2-27.
Test profile developed in accordance with
MIL-PRF-28800F.
Random vibration
Operating ..................................................5 Hz to 500 Hz, 0.3 g
rms
Nonoperating ............................................5 Hz to 500 Hz, 2.4 g
rms
,
tested in accordance with IEC-60068-2-64.
Nonoperating test profile exceeds the
requirements of MIL-PRF-28800F, Class 3.
Safety
This product meets the requirements of the following standards of safety for electrical equipment
for measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
1
For PXI/PXI Express chassis configurations that group NI FlexRIO adapter modules in three or more
contiguous slots, National Instruments recommends limiting the ambient operating temperature to less
than 50
°
C.