Chapter 7
Counters
©
National Instruments Corporation
7-29
Routing a Signal to Counter
n
Aux
Each counter has independent input selectors for the Counter
n
Aux signal.
Any of the following signals can be routed to the Counter
n
Aux input.
•
RTSI <0..7>
•
Input PFI <0..5>
•
ai/ReferenceTrigger
•
ai/StartTrigger
•
PXI_STAR
In addition, Counter 1 Internal Output, Counter 1 Gate, Counter 1 Source,
or Counter 0 Gate can be routed to Counter 0 Aux. Counter 0 Internal
Output, Counter 0 Gate, Counter 0 Source, or Counter 1 Gate can be routed
to Counter 1 Aux.
Some of these options may not be available in some driver software.
Counter
n
A, Counter
n
B, and Counter
n
Z Signals
Counter
n
B can control the direction of counting in edge counting
applications.
Use the A, B, and Z inputs to each counter when measuring quadrature
encoders or measuring two pulse encoders.
Routing Signals to A, B, and Z Counter Inputs
Each counter has independent input selectors for each of the A, B, and Z
inputs. Any of the following signals can be routed to each input.
•
RTSI <0..7>
•
Input PFI <0..5>
•
PXI_STAR
Routing Counter
n
Z Signal to an Output Terminal
You can route Counter
n
Z out to RTSI <0..7>.
Counter
n
Up_Down Signal
Counter
n
Up_Down is another name for the Counter
n
B signal.