National Instruments Corporation
1-1
R Series Intelligent DAQ User Manual
1
Introduction
This chapter describes the NI 781
x
R/783
x
R/784
x
R/785
x
R, the concept of
the Reconfigurable I/O (RIO) device, optional software and equipment for
using the NI 78
xx
R, and safety information about the NI 78
xx
R.
About the Reconfigurable I/O Device
Table 1-1 lists an overview of the NI 78
xx
R R Series Intelligent DAQ RIO
devices.
A user-reconfigurable FPGA (Field-Programmable Gate Array) controls
the digital I/O lines on the NI 781
x
R, and the digital and analog I/O lines
on the NI 783
x
R/784
x
R/785
x
R. The FPGA on the R Series device allows
you to define the functionality and timing of the device. You can change the
functionality of the FPGA on the R Series device in LabVIEW using the
LabVIEW FPGA Module to create and download a custom virtual
Table 1-1.
NI 78
xx
R R Series Intelligent DAQ RIO Device Overview
Device
I/O Channels
FPGA
AI Sample Rate
NI PCI/PXI-7811R
160 DIO
Virtex-II XC2V1000
—
NI PCI/PXI-7813R
160 DIO
Virtex-II XC2V3000
—
NI PCI/PXI-7830R
4 AI, 4 AO, 56 DIO
Virtex-II XC2V1000
200 kS/s
NI PCI/PXI-7831R
8 AI, 8 AO, 96 DIO
Virtex-II XC2V1000
200 kS/s
NI PCI/PXI-7833R
8 AI, 8 AO, 96 DIO
Virtex-II XC2V3000
200 kS/s
NI PXI-7841R
8 AI, 8 AO, 96 DIO
Virtex-5 LX30
200 kS/s
NI PXI-7842R
8 AI, 8 AO, 96 DIO
Virtex-5 LX50
200 kS/s
NI PXI-7851R
8 AI, 8 AO, 96 DIO
Virtex-5 LX30
750 kS/s
NI PXI-7852R
8 AI, 8 AO, 96 DIO
Virtex-5 LX50
750 kS/s
NI PXI-7853R
8 AI, 8 AO, 96 DIO
Virtex-5 LX85
750 kS/s
NI PXI-7854R
8 AI, 8 AO, 96 DIO
Virtex-5 LX110
750 kS/s
Summary of Contents for NI 781 R Series