Chapter 2
Hardware Overview of the NI 78xxR
©
National Instruments Corporation
2-19
R Series Intelligent DAQ User Manual
Figure 2-11.
Example Digital I/O Connections
Figure 2-11 shows DIO<0..3> configured for digital input and DIO<4..7>
configured for digital output. Digital input applications include receiving
TTL, LVTTL, CMOS, or LVCMOS signals and sensing external device
states, such as the state of the switch shown in Figure 2-11. Digital output
applications include sending TTL or LVCMOS signals and driving external
devices, such as the LED shown in Figure 2-11.
The NI 78
xx
R SHC68-68-RDIO cable contains individually shielded
bundles that route each digital signal on an individually shielded pair of
wires, and each signal is twisted with its own wire to digital ground.
*3.3 V CMOS
†
Use a pull-up resistor when driving 5 V CMOS devices.
LED
TTL, LVTTL, CMOS, or LVCMOS Signal
+5 V
Switch
I/O Connector
DGND
NI 783
x
R/784
x
R/785
x
R
DIO<0..3>
DIO<4..7>
+5 V
5 V CMOS
†
TTL or
LVCMOS*
Compatible
Devices
DGND
Summary of Contents for NI 781 R Series