Chapter 2
Hardware Overview of the NI 783xR
©
National Instruments Corporation
2-23
4.
Reinsert the NI 783
x
R into the PXI/CompactPCI chassis or PCI
computer. Refer to the
Installing the Hardware
section of the
Getting
Started with the NI
783
x
R
document for installation instructions.
5.
Plug in and power on the PXI/CompactPCI chassis or PCI computer.
After completing this procedure, a VI stored in Flash memory does not load
to the FPGA at power-on. You can use software to configure the NI 783
x
R
if necessary. To return to the defaults of loading from Flash memory, repeat
the previous procedure but return SW1 to the OFF position in step 3. You
can use this switch to enable/disable the ability to load from Flash memory.
In addition to this switch, you must configure the NI 783
x
R with the
software to autoload an FPGA VI.
Note
When the NI 783
x
R is powered on with SW1 in the ON position, the analog circuitry
does not return properly calibrated data. Move the switch to the ON position only while
you are using software to reconfigure the NI 783
x
R for the desired power-up behavior.
Afterward, return SW1 to the OFF position.
Power Connections
Two pins on each I/O connector supply 5 V from the computer power
supply using a self-resetting fuse. The fuse resets automatically within a
few seconds after the overcurrent condition is removed. The +5V pins are
referenced to DGND and can power external digital circuitry. The
NI 783
x
R has the following power rating:
+4.50 to +5.25 VDC at 1 A (250 mA max per +5V pin, 1 A max total for
all +5V lines on the device)
Caution
Do
not
connect the +5V power pins directly to analog or digital ground or to any
other voltage source on the NI 783
x
R or any other device under any circumstance. Doing
so can damage the NI 783
x
R and the computer. NI is
not
liable for damage resulting from
such a connection.