NI 9144 User Guide and Specifications
|
© National Instruments
|
23
C Series
Module
0x2000
0
U32
R
NI C Series Vendor ID
(for NI C Series modules, equals
0x1093)
0x2001
0..N
ARR:
R/W
• Scan or command list
• Channel direction control
• Mode selection
0x2002
0
U32
R/W
• Error status
• Unipolar/bipolar control
• Module configuration
command
• Module conversion rate
control
0x2003
0
U32
R/W
Error acknowledgement
(or status)
0x2005
0
U8
R/W
• Refresh period
• Conversion format
0x2100
0..N
ARR:
R
Calibration data
0x3002
0
U32
R
Number of scans. This index
reports the number of
conversions the module makes
during the cycle. If disable
multiple scans is selected, the
number of scans is always 1.
0x4000
…
0x47FF
—
—
R/W
Safe data values that mirror the
PDO data in 0x6000…0x67FF.
0x4800
…
0x4FFF
—
—
R/W
Safe control values that mirror the
SDO data in 0x2000…0x27FF.
Table 3.
Module Vendor Extensions (Continued)
Vendor
Extension
Index
Sub
Type
R/W
Description