3
8
|
ni.com
|
NI 9144 User Guide and Specifications
NI 9212
The vendor configuration extensions for the NI 9212 are listed in Table 26.
NI 9212 Conversion Speed Control
The NI 9212 can convert channels at four pre-defined rates, as controlled by the speed control
field. Table 27 lists the conversion speed controls.
Note
The conversion rate assumes that 40 channels are in the scan list.
NI 9212 Status
The error/status field is defined as listed in Table 28.
Table 26.
NI 9212 Vendor Configuration Extensions
Index
Sub
Type
R/W
Description
0x2002
—
U32
R/W
Channel Speed Control = 2, 8, 9 or
15, default = 15
0x2003
—
ARR:U32
R
Open Thermocouple Status (also as
8-bit PDO)
Table 27.
NI 9212 Conversion Speed Control
Speed Control
Meaning
Conversion Rate
2 (0x02)
High-Speed
10.39 ms/module
8 (0x08)
Best 60 Hz Rejection
138 ms/module
9 (0x09)
Best 50 Hz Rejection
117.49 ms/module
15 (0x0F)
High-Resolution
548.2 ms/module
Table 28.
NI 9212 Open Thermocouple Status Code
Bits
Field
31..8
Reserved
7..0
The latest detected open thermocouple status. Each
channel takes one bit.