Getting Started with NI 9514/16 Modules and AKD Servo Drives
accuracy. If you select a different value for
Resolution
, remember to update the
Counts Per revolution
setting in the
Axis Configuration
dialog box.
d. Set the
Index Offset
to 0.
Figure 19 shows the AKD WorkBench Encoder Emulation page.
Figure 19.
AKD WorkBench Encoder Emulation Page
9. Configure the analog input command scaling.
a. Expand the
Settings
tree item and open the
Motor
page.
b. Write down the motor
Continuous Current
value.
Note
Motor continuous current is in Arms.