4
|
ni.com
|
Getting Started with NI 9514/16 Modules and AKD Servo Drives
Hardware Installation and Configuration
This section covers the hardware setup for the CompactRIO system, NI 9514 or NI 9516
C Series module, and AKD servo drive.
Figure 2 shows an overview of the connectors on the AKD servo drive.
Figure 2.
AKD Servo Drive Connectors
1
24 V Supply, STO (X1)
2
Motor, Brake (X2)
3
AC Input Power (X3)
4
Encoder Emulation (X9)
5
Drive Grounding Lug
6
Feed
b
ack (X10)
7
I/O Connector (X8)
8
I/O Connector (X7)
9
Static IP Addressing Switch (S2)
10 Static IP Addressing Switch (S1)
11 Drive Communication (X11)
12 LED Indicators
1
2
3
6
4
11
9
10
7
5
12
8
Summary of Contents for NI 9514