National Instruments Corporation
31
NI 9792 WSN Real-Time User Guide and Specifications
The NI 9792 is designed to meet the requirements of the following standards of safety for electrical
equipment for measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Hazardous Locations
U.S. (UL) ...............................................................Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, AEx nC IIC T4
Canada (C-UL) ......................................................Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, Ex nA IIC T4
Europe (DEMKO)..................................................Ex nA nL IIC T4
Note
For UL and other safety certifications, refer to the product label, or go to
ni.com/
certification
, search by model number or product line, and click the appropriate link in the
Certification column.
Safety Voltages
Connect only voltages that are within these limits.
V terminal to C terminal ........................................35 V max, Measurement Category I
Measurement Category I is for measurements performed on circuits not directly connected to the
electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply
system that powers equipment. This category is for measurements of voltages from specially protected
secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy
parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Caution
Do not connect the system to signals or use for measurements within Measurement
Categories II, III, or IV.
RF Safety Warning
This product complies with FCC radiation exposure limits set for uncontrolled equipment and meets the
FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. This product generates and
radiates radio frequency energy. To comply with the radio frequency radiation exposure guidelines in an
uncontrolled environment, this equipment should be installed and operated with at least 20 cm between
the radiator and the person’s body (excluding extremities: hands, wrists, feet, and legs).
This product complies with the European Council Recommendation (1995/519/EC) on the limitation of
exposure of the general public to electromagnetic fields. Compliance was determined in accordance
with the requirements in EN 50371.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of EMC for electrical
equipment for measurement, control, and laboratory use:
•
EN 61326-1 (IEC 61326-1): Class A emissions; Basic Immunity
•
EN 55011 (CISPR 11): Group 1, Class A emissions
•
AS/NZS CISPR 11, Group 1, Class A emissions
•
FCC 47 CFR Part 15B: Class A emissions
•
ICES-001: Class A emissions