NI 9852 Operating Instructions
16
ni.com
Specifications
The following specifications are typical for the range –40 to 70 °C
unless otherwise noted.
Low-Speed/Fault-Tolerant CAN Characteristics
Transceiver........................................ Philips TJA1054A
Max baud rate ................................... 125 Kbps
CAN_H, CAN_L bus lines
voltage............................................... –27 to +40 VDC
Supply voltage range (V
SUP0
/V
SUP1
)
CAN0 ......................................... +8 to +36 VDC
CAN1 ......................................... +8 to +36 VDC
R
RTH
............................................ 1.11 k
Ω
±
0.5% or
4.99 k
Ω
±
0.5%
R
RTL
............................................ 1.11 k
Ω
±
0.5% or
4.99 k
Ω
±
0.5%
MTBF ............................................... 1,052,836 hours at 25 °C;
Bellcore Issue 6, Method 1,
Case 3, Limited Part Stress
Method