Electromagnetic Compatibility
■
EN 61326 (IEC 61326): Class A emissions; Industrial immunity
CE Compliance
■
2014/34/EU; Potentially Explosive Atmospheres (ATEX)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory
compliance information. To obtain product certifications and the DoC for NI
products, visit
, search by model number, and click the
appropriate link.
Shock and Vibration
To meet these specifications, you must panel mount the system.
Operating vibration
Random
5 g RMS, 10 Hz to 500 Hz
Sinusoidal
5 g, 10 Hz to 500 Hz
Operating shock
30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations
Environmental
Refer to the manual for the chassis you are using for more information about
meeting these specifications.
Operating temperature (IEC 60068-2-1, IEC 60068-2-2)
-40 °C to 70 °C
Storage temperature (IEC 60068-2-1, IEC 60068-2-2)
-40 °C to 85 °C
Ingress protection
IP40
Operating humidity (IEC 60068-2-30)
10% RH to 90% RH, noncondensing
© National Instruments
11
NI-9852 Getting Started