Cabling Requirements for the NI 9852
Cable Specifications
Cables should meet the physical medium requirements specified
in ISO 11898, shown in the following table. Belden cable
(3084A) meets all these requirements and should be suitable for
most applications.
Table 3.
ISO 11898 Specifications for Characteristics of a CAN_H and
CAN_L Pair of Wires
Characteristic
Value
Length-related resistance
90 mΩ/m nominal
Length-related capacitance: CAN_L and ground,
CAN_H and ground, CAN_L and CAN_H
30 pF/m nominal
NI 9852 Getting Started Guide
|
© National Instruments
|
11