NI 9852 Hardware Overview
The NI 9852 has two full-featured, independent CAN ports that are isolated from
each other, and from the other modules in the system. Each port on the NI 9852 has
a Philips SJA1000 controller that is CAN 2.0B-compatible and fully supports both 11-
bit and 29-bit identifiers. The port also has a Philips TJA1054A Low-Speed/Fault-
Tolerant CAN transceiver that is fully compatible with the ISO 11898 standard and
supports baud rates up to 125 Kbps.
Figure 3. NI 9852 Hardware Overview
NI 9852 Specifications
The following specifications are typical for the range -40 °C to 70 °C unless otherwise
noted.
Low-Speed/Fault Tolerant CAN Characteristics
Transceiver
Philips TJA1054A
Max baud rate
125 Kbps
CAN_H, CAN_L bus lines voltage -27 to +40 VDC
Supply voltage range (V
SUP0
/V
SUP1
)
CAN0
+8 to +36 VDC
CAN1
+8 to +36 VDC
R
RTH
1.11 kΩ ± 0.5% or 4.99 kΩ ± 0.5%
R
RTL
1.11 kΩ ± 0.5% or 4.99 kΩ ± 0.5%
MTBF
1,052,836 hours at 25 °C; Bellcore Issue 6, Method 1, Case 3,
Limited Part Stress Method
ni.com
8
NI-9852 Getting Started