NI 9853 Operating Instructions
Specifications
The following specifications are typical for the range –40 to 70 °C
unless otherwise noted.
High-Speed CAN Characteristics
Transceiver........................................ Philips TJA1041
Max baud rate ................................... 1 Mbps
CAN_H, CAN_L bus lines
voltage............................................... –27 to +40 VDC
Supply voltage range (V
SUP
)
CAN0 ......................................... N/A
CAN1 ......................................... +8 to +25 VDC
MTBF ............................................... 1,816,913 hours at 25 °C;
Bellcore Issue 6, Method 1,
Case 3, Limited Part Stress
Method
Note
Contact NI for Bellcore MTBF specifications at
other temperatures or for MIL-HDBK-217F
specifications.