NI 9871 Operating Instructions
Pollution Degree (IEC 60664) .......... 2
Maximum altitude............................. 5,000 m
Indoor use only
Shock and Vibration
To meet these specifications, you must panel mount the
CompactRIO system.
Operating vibration,
random (IEC 60068-2-64) ................ 5 g
rms
, 10 to 500 Hz
Operating shock (IEC 60068-2-27).... 30 g, 11 ms half sine,
50 g, 3 ms half sine,
18 shocks at 6 orientations
Operating vibration,
sinusoidal (IEC 60068-2-6) .............. 5 g, 10 to 500 Hz