Figure 13. Installing an I/O Module in the Chassis (Eight-Slot Chassis Shown)
1
2
1. Insertion Groove
2. Latch
3.
Squeeze the latches and insert the I/O module into the module slot.
4.
Press firmly on the connector side of the I/O module until the latches lock the I/O module
into place.
5.
Repeat these steps to install additional I/O modules.
Removing I/O Modules from the Chassis
Complete the following steps to remove a C Series I/O module from the chassis.
1.
Make sure that no I/O-side power is connected to the I/O module. If the system is in a
nonhazardous location, the chassis power can be on when you remove I/O modules.
2.
Squeeze the latches on both sides of the module and pull the module out of the chassis.
Connecting the Chassis to Earth Ground
You must connect the panhead screw at the end of the chassis to ground using shielded cables.