Power Requirements
These power requirements are for a fully loaded chassis and exclude the power requirements
of the controller and the I/O modules in the chassis. For more information about the controller
and the I/O module power requirements, refer to the controller and module documentation on
Chassis power consumption/dissipation
cRIO-9111 and cRIO-9112
+5 VDC
500 mW maximum
+3.3 VDC
2,100 mW maximum
Total chassis power
consumption
2,600 mW maximum
cRIO-9113 and cRIO-9114
+5 VDC
500 mW maximum
+3.3 VDC
2,800 mW maximum
Total chassis power
consumption
3,300 mW maximum
cRIO-9116
+5 VDC
500 mW maximum
+3.3 VDC
4,600 mW maximum
Total chassis power
consumption
5,100 mW maximum
cRIO-9118
+5 VDC
500 mW (max)
+3.3 VDC
5,400 mW (max)
Total chassis power
consumption
5,900 mW maximum
Note
The power consumption specifications in this document are maximum values
for a LabVIEW FPGA application compiled at 80 MHz. Your application power
requirements may be different. To calculate the power requirements of the
CompactRIO system, add the power consumption/dissipation for the chassis, the
controller, and the I/O modules you are using. Keep in mind that the resulting total
power consumption is a maximum value and that the CompactRIO system may
require less power in your application.
NI cRIO-9111/9112/9113/9114/9116/9118
|
© National Instruments
|
15