NI DIDS-2100 Series User Manual | © National Instruments | 185
Reset
Tip Strip: Resets TDK High Voltage power supply
GEN Control Mode
Tip Strip: Indicates TDK High Voltage Power Supply Control Mode
Detail: By default the TDK supply control mode should be in LOCKOUT mode which means the device front
panel will be inoperable.
OverVoltage Limit
Tip Strip: TDK Genesys Power High Voltage Power Supply OverVoltage Protection
Detail: The OverVoltage limit is set to 195V. The external high voltage supply to be applied to the DI Driver
module is limited to 190V and thus the limit on the
GEN Voltage Limit
parameter. This should giveenough room for
the user to operate up to 190V without error.
GEN Address
Tip Strip: TDK Genesys Power Supply instrument address
Detail: By default the TDK supply instrument address is set to 6.
GEN BaudRate
Tip Strip: TDK Genesys Power Supply instrument RS232 serial communication baud rate (Default = 9600)
Detail: By default, the serial communication with the instrument is set to 9600.
Output Enable
Tip Strip:
Enables Current output on the TDK Lambda High Voltage Supply
Summary of Contents for NI DIDS-2103
Page 11: ...NI DIDS 2100 Series User Manual National Instruments 11 3 2 Software...
Page 32: ...32 ni com NI DIDS 2100 Series User Manual...
Page 40: ...40 ni com NI DIDS 2100 Series User Manual 3 3 Hardware...
Page 44: ...44 ni com NI DIDS 2100 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 174: ...174 ni com NI DIDS 2100 Series User Manual Aux PWX 2 4 See above descriptions...
Page 210: ...210 ni com NI DIDS 2100 Series User Manual 12 Connecting Port Fuel Injectors to the PFI Driver...
Page 214: ...214 ni com NI DIDS 2100 Series User Manual 16 9066 RS 232 Serial Connector to TDK Power Supply...
Page 216: ...216 ni com NI DIDS 2100 Series User Manual 8 Important Information...
Page 223: ...NI DIDS 2100 Series User Manual National Instruments 223...