190 | ni.com | NI DIDS-2100 Series User Manual
4.19 Log Data Setup Window
The purpose of the Log Data Setup window is to configure data logging of a variety of DI Driver System software
parameters to a text file, stored on the cRIO controller file system. The data files are NOT able to be logged over the
network to another computer. After the data logging is completed, the data file may be copied to another computer
via File Transfer Protocol (FTP) connection over the network. Options for logging data include Sample Period,
RAM Buffer Size, Stop Trigger, Filename Suffix, and Data Delimiter. The variables to be logged are specified in an
array of drop-down selection lists. A logging parameter plot is available within the window and parameters may be
individually selected for plotting.
Log File Directory
Tip Strip: Determines location where data file is saved on DI Driver System controller
Detail: Specifies the location on the cRIO controller where the log file will be saved. Two choices are
available:
Target LabVIEW Data Directory
and
USB Storage Device
. If
Target LabVIEW Data Directory
is selected, then the file can be retrieved via an FTP browser from the location "/home/lvuser/natinst/
LabVIEW Data". (Previous DI Driver Systems based on the cRIO-9022, cRIO-9076, and cRIO-9082 have
their LabVIEW Data directories located at “c:\ni-rt\LabVIEW Data”.) File Paths starting with c:\ indicates that
the log file will be saved to the cRIO controller local hard drive. Data files can optionally be stored to a USB
storage device if connected via the USB port on the cRIO controller front panel. Typically, a USB storage
device will be shown in the controller file browser as u:\.
USB Drive Present
Tip Strip: Indicates presence of external memory at USB connector
Summary of Contents for NI DIDS-2103
Page 11: ...NI DIDS 2100 Series User Manual National Instruments 11 3 2 Software...
Page 32: ...32 ni com NI DIDS 2100 Series User Manual...
Page 40: ...40 ni com NI DIDS 2100 Series User Manual 3 3 Hardware...
Page 44: ...44 ni com NI DIDS 2100 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 174: ...174 ni com NI DIDS 2100 Series User Manual Aux PWX 2 4 See above descriptions...
Page 210: ...210 ni com NI DIDS 2100 Series User Manual 12 Connecting Port Fuel Injectors to the PFI Driver...
Page 214: ...214 ni com NI DIDS 2100 Series User Manual 16 9066 RS 232 Serial Connector to TDK Power Supply...
Page 216: ...216 ni com NI DIDS 2100 Series User Manual 8 Important Information...
Page 223: ...NI DIDS 2100 Series User Manual National Instruments 223...