88 | ni.com | NI DIDS-2100 Series User Manual
ModeSelectVRHall_ChX
Tip Strip: Mode select for VR/Hall Channel
Detail: Selects the mode of operation for each channel of the NI 9760.
VR Adaptive Arm:
Disabled pull-up resistor. Self-adaptive arming threshold for zero-crossing detection.
VR Manual Arm:
Disabled pull-up resistor. Manually (or programmatically) set arming threshold for zero-
crossing detection.
Hall:
Disabled pull-up resistor. Manually (or programmatically) set logic threshold (no zero-crossing
detection)
Hall w/ Pull-up:
Enabled pull-up resistor. Manually (or programmatically) set logic threshold (no zero-
crossing detection)
See hardware manual for a more detailed description of each operating mode.
Arming_ThresholdVoltageVRHall_ChX
Tip Strip: Assigns digital signal source to channel during Direct and TMP Modes
Detail: Arming (VR) or logic (Hall) threshold voltages used in 'VR Manual Arm' or Hall modes of operation.
Min=0V, Max=2.97V.
Summary of Contents for NI DIDS-2103
Page 11: ...NI DIDS 2100 Series User Manual National Instruments 11 3 2 Software...
Page 32: ...32 ni com NI DIDS 2100 Series User Manual...
Page 40: ...40 ni com NI DIDS 2100 Series User Manual 3 3 Hardware...
Page 44: ...44 ni com NI DIDS 2100 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 174: ...174 ni com NI DIDS 2100 Series User Manual Aux PWX 2 4 See above descriptions...
Page 210: ...210 ni com NI DIDS 2100 Series User Manual 12 Connecting Port Fuel Injectors to the PFI Driver...
Page 214: ...214 ni com NI DIDS 2100 Series User Manual 16 9066 RS 232 Serial Connector to TDK Power Supply...
Page 216: ...216 ni com NI DIDS 2100 Series User Manual 8 Important Information...
Page 223: ...NI DIDS 2100 Series User Manual National Instruments 223...