NI DIDS-2100 Series User Manual | © National Instruments | 103
Duration Ch1 (msec)
Tip Strip: Duration of injection pulse
Units: msec
Detail: Specifies the time duration of the injection pulse. The
ON/OFF
parameter determines whether the pulse will be active or inactive.
Duration Ch1 (CAD)
Tip Strip: Duration of injection pulse
Units: CAD
Detail: This parameter is always disabled, but automatically updated with a calculated value. It is calculated
based on
(msec) and
Engine Position Tracking Setup
window.
DIX Timing Mode
Tip Strip: Selects timing mode of each injection pulse as Start Of Injection or End Of Injection
Detail: Selector for choosing between Start of Injection “SOI” Mode and End of Injection “EOI” Mode. When
SOI
mode is selected, the
EOI
Timing parameters will be disabled and retain their most recently entered end
of injection angle. When
EOI
mode is selected, the
SOI
Timing parameters will be disabled and retain their
most recently entered start of injection angle.
Enable Individual DI1 Channel Duration
Tip Strip: Defines whether the DI Driver module is in uniform or individual mode.
Individual Channel Duration Indicator
.
Duration Ch2 and Ch3
Detail: Please see information for channel 1
Summary of Contents for NI DIDS-2103
Page 11: ...NI DIDS 2100 Series User Manual National Instruments 11 3 2 Software...
Page 32: ...32 ni com NI DIDS 2100 Series User Manual...
Page 40: ...40 ni com NI DIDS 2100 Series User Manual 3 3 Hardware...
Page 44: ...44 ni com NI DIDS 2100 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 174: ...174 ni com NI DIDS 2100 Series User Manual Aux PWX 2 4 See above descriptions...
Page 210: ...210 ni com NI DIDS 2100 Series User Manual 12 Connecting Port Fuel Injectors to the PFI Driver...
Page 214: ...214 ni com NI DIDS 2100 Series User Manual 16 9066 RS 232 Serial Connector to TDK Power Supply...
Page 216: ...216 ni com NI DIDS 2100 Series User Manual 8 Important Information...
Page 223: ...NI DIDS 2100 Series User Manual National Instruments 223...