HPV_MinDC
Tip Strip: Minimum allowed duty cycle for HPV
Units: %
Detail: Minimum allowed duty cycle for HPV
HPV_DC
Tip Strip: Final HPV duty cycle
Units: %
Detail: Final duty cycle applied to the HPV solenoid.
HPV_NomResistance
Tip Strip: Nominal resistance of HPV solenoid
Units: Ohms
Detail: Nominal resistance of the HPV solenoid. This value is used to calculate the maximum duty cycle
applied to the HPV. It is important to measure this resistance /-0.5 ohms
HPV_Current
Tip Strip: Estimated current to HPV based on battery voltage and nominal solenoid resistance
Units: A
Detail: An estimate of the current flowing through the HPV based on the duty cycle, battery voltage, and the
nominal resistance of the valve.