background image

ni.com/mydaq

Contents I Contenu I Inhalt 

内容

 I 

내용

 I 

内容

NI myDAQ

Quick Start 
Démarrage rapide
Erste Schritte 

クイックスタート

시작하기

快速入门

373059C-01

 

May16

Caution

     Before installing your device, read all product  

documentation to ensure compliance with safety, EMC, and 

environmental regulations.

Attention

     Avant d’installer votre périphérique, lisez toute la  

documentation se rapportant au produit pour vous assurer du respect 

des règles concernant la sécurité, la CEM et l’environnement.

Achtung

     Lesen Sie vor dem Einbauen des Geräts die  

Produktdokumentation, um sich über alle einzuhaltenden Sicherheits-

vorschriften, EMV-Vorschriften und Umweltrichtlinien zu informieren.

注意     

デバイスを取り付ける前に、すべての製品ドキュメントをお読みに

なり、安全、

EMC

、環境規制を遵守してください。

주의

      

디바이스를 설치하기 전에 모든 제품 관련 문서를 읽고 안전, 

EMC

, 환경 규정을 준수하는지 확인하십시오.

警告   安装设备之前,请阅读所有产品文档,确保符合安全、

EMC

及环境法规。

Useful Links I Liens utiles I Nützliche Links 

役に立つリンク 

유용한 링크

 I 

相关链接 

Getting Started/Support

ni.com/mydaq

/support

Specifications

ni.com/inf

o

a

mydaqspecs

Software

ni.com/do

wnloads

© 

2012–2016 National Instruments Corp.  

All rights reserved.

DEVICE CONNECTIONS

Screw Terminal Connections

•   +15V

: Pow

er supply (32 mA max output current

1

)

•   –15V

: Pow

er supply (32 mA max output current

1

)

•   AGND: Ground f

or ±15 

V pow

er supplies, A

O, and 

AI

•   A

O: Analog output (±1

0 V, 20

0 kSamples/second max update rate, 2 mA max  

     output cur

rent per 

line

1

)

•   AGND: Ground f

or ±15 

V pow

er supplies, A

O, and 

AI

•   AI: 

Analog input (±10 

V , 20

0 kSamples/second max sample rate)

•   DIO: 5 V compatible L

VTTL input, 3.3 V L

VTTL output (4 mA max output

     current per line

1

)

•   DGND: Ground for DIO and 5 

V pow

er supply

•   +5V: P

ow

er supply (4.0 to 5.2 V, 1

00 mA max output cur

rent

1

)

Interface Connections

•   USB: Type 

A to B, direct connect or po

wered hub only

DMM Connections

•   HI [V , 

,   ]: 

Volt

age, resistance, and diode measurement positiv

e input terminal

     (60 VDC, 20 

Vrms max input volt

age)

•   COM: Common reference f

or all DMM measurements

•   HI [A]: Current measurement positiv

e input terminal (1 A max input cur

rent)

Audio Connections

•   AUDIO IN: 3.5 mm stereo jac

k (±2 V LINE IN or microphone)

•   AUDIO O

UT: 3.5 mm stereo jac

k (±2 V LINE O

UT)

1

Tot

al pow

er is limited to 500 mW (t

ypical)/100 mW (minimum) f

or all outputs and supplies. 

Ref

er to the 

NI myD

AQ User Guide and Specifications

 for ho

w to calculate total po

wer

.

Projects and Example Code

ni.com/m

ydaqz

one

USB Cable

DMM Cables

Terminal Connector

Soft

ware

Audio Cables

NI my

DAQ

NI my

DAQ

Analog ICs 

 supplied by

 

Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for more information on National 

 

Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their  

respective companies. For patents covering National Instruments products/technology, refer to the appropriate 

 

location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments 

 

Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and 

 

third-party legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information

 at 

ni.com/ 

legal/export-compliance

 for the National Instruments global trade compliance policy and how to obtain

relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE  

ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. 

 

Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable  

limited rights and restricted data rights as 

set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

NI myDAQ User Manual

ni.com/inf

o

a

mydaqug

Summary of Contents for NI myDAQ

Page 1: ...M Connections HI V Ω Voltage resistance and diode measurement positive input terminal 60 VDC 20 Vrms max input voltage COM Common reference for all DMM measurements HI A Current measurement positive input terminal 1 A max input current Audio Connections AUDIO IN 3 5 mm stereo jack 2 V LINE IN or microphone AUDIO OUT 3 5 mm stereo jack 2 V LINE OUT 1 Total power is limited to 500 mW typical 100 mW ...

Page 2: ... AO and AI AO Analog output 10 V 200 kSamples second max update rate 2 mA max output current per line1 AGND Ground for 15 V power supplies AO and AI USB Cable NI myDAQ NI myDAQ Refer to the NI Trademarks and Logo Guidelines at ni com trademarks for more information on National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective ...

Page 3: ...t Launcherを選択します Digital Multimeterをクリックします 시작 모든 프로그램National Instruments NI ELVISmx for NI ELVIS NI myDAQ NI ELVISmx Instrument Launcher를를 선택합니다 Digital Multimeter을 클릭합니다 4 4 Specify Range Run Continuously Dev1 NI myDAQ or the device number of your myDAQ 20 V 3 3 2 2 1 1 从光盘安装 或从ni com downloads下载安装程序进行安装 先安装LabVIEW等应用程序开发软 件 然后安装NI ELVISmx驱动程序 选择开始 所有程序 National Instruments NI ELVISmx for NI EL...

Page 4: ...t Launcherを選択します Digital Multimeterをクリックします 시작 모든 프로그램National Instruments NI ELVISmx for NI ELVIS NI myDAQ NI ELVISmx Instrument Launcher를를 선택합니다 Digital Multimeter을 클릭합니다 4 4 Specify Range Run Continuously Dev1 NI myDAQ or the device number of your myDAQ 20 V 3 3 2 2 1 1 从光盘安装 或从ni com downloads下载安装程序进行安装 先安装LabVIEW等应用程序开发软 件 然后安装NI ELVISmx驱动程序 选择开始 所有程序 National Instruments NI ELVISmx for NI EL...

Reviews: