Appendix A
Specifications
©
National Instruments Corporation
A-9
NI PXI-1031/PXI-1031DC User Manual
Note
For UL and other safety certifications, refer to the product label, or visit
ni.com/certification
, search by model number or product line, and click the
appropriate link in the Certification column.
Electromagnetic Compatibility
Emissions ............................................... EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
1
Immunity ................................................ EN 61326:1997 + A2:2001,
Table 1
EMC/EMI............................................... CE, C-Tick, and FCC Part 15
(Class A) Compliant
Note
For EMC compliance, operate this device with shielded cabling. In addition,
all covers and filler panels must be installed.
CE Compliance
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
Low-Voltage Directive (safety) ............. 73/23/EEC
Electromagnetic Compatibility
Directive (EMC) .................................... 89/336/EEC
Note
Refer to the Declaration of Conformity (DoC) for this product for any additional
regulatory compliance information. To obtain the DoC for this product, visit
ni.com/certification
, search by model number or product line, and click the
appropriate link in the Certification column.
Backplane
Size......................................................... 3U-sized; one system slot
(with three system expansion
slots) and three peripheral slots.
Compliant with IEEE 1101.10
mechanical packaging.
PXI Hardware Specification
compliant. Accepts both PXI
and CompactPCI 3U modules.
1
DC input exempt from emissions requirements.