background image

Appendix B

Pinouts

NI PXI-1056 User Manual

B-2

ni.com

 

Table B-1.  

P1 (J1) Connector Pinout for the System Controller Slot

Pin

Z

A

B

C

D

E

F

25

GND

5V

REQ64#

ENUM#

3.3V

5V

GND

24

GND

AD[1]

5V

V(I/O)

AD[0]

ACK64#

GND

23

GND

3.3V

AD[4]

AD[3]

5V

AD[2]

GND

22

GND

AD[7]

GND

3.3V

AD[6]

AD[5]

GND

21

GND

3.3V

AD[9]

AD[8]

M66EN

C/BE[0]#

GND

20

GND

AD[12]

GND

V(I/O)

AD[11]

AD[10]

GND

19

GND

3.3V

AD[15]

AD[14]

GND

AD[13]

GND

18

GND

SERR#

GND

3.3V

PAR

C/BE[1]#

GND

17

GND

3.3V

IPMB_SCL

IPMB_SDA

GND

PERR#

GND

16

GND

DEVSEL#

GND

V(I/O)

STOP#

LOCK#

GND

15

GND

3.3V

FRAME#

IRDY#

GND

TRDY#

GND

12–14

Key Area

11

GND

AD[18]

AD[17]

AD[16]

GND

C/BE[2]#

GND

10

GND

AD[21]

GND

3.3V

AD[20]

AD[19]

GND

9

GND

C/BE[3]#

GND

AD[23]

GND

AD[22]

GND

8

GND

AD[26]

GND

V(I/O)

AD[25]

AD[24]

GND

7

GND

AD[30]

AD[29]

AD[28]

GND

AD[27]

GND

6

GND

REQ0#

GND

3.3V

CLK0

AD[31]

GND

5

GND

BRSVP1A5

BRSVP1B5

RST#

GND

GNT0#

GND

4

GND

IPMB_PWR

HEALTHY#

V(I/O)

INTP

INTS

GND

3

GND

INTA#

INTB#

INTC#

5V

INTD#

GND

2

GND

TCK

5V

TMS

TDO

TDI

GND

1

GND

5V

 –12V

TRST#

 +12V

5V

GND

Summary of Contents for NI PXI-1056

Page 1: ...PXI NI PXI 1056 User Manual NI PXI 1056 User Manual September 2005 371551A 01...

Page 2: ...orea 82 02 3451 3400 Lebanon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 3390150 Portugal 35...

Page 3: ...lood accident actions of third parties or other events outside reasonable control Copyright Under the copyright laws this publication may not be reproduced or transmitted in any form electronic or mec...

Page 4: ...Interoperability with CompactPCI 1 5 System Controller Slot 1 5 Star Trigger Slot 1 5 Peripheral Slots 1 6 Local Bus 1 6 Trigger Bus 1 8 System Reference Clock 1 8 Chapter 2 Installation and Configura...

Page 5: ...Using System Configuration and Initialization Files 2 17 Chapter 3 Maintenance Service Interval 3 1 Preparation 3 1 Cleaning 3 1 Interior Cleaning 3 2 Exterior Cleaning 3 2 Cleaning and Replacing the...

Page 6: ...ystem crash When this symbol is marked on the product refer to the Read Me First Safety and Radio Frequency Interference document shipped with the product for precautions to take bold Bold text denote...

Page 7: ...manual CompactPCI Specification PICMG 2 0 R 3 0 PXI Hardware Specification Revision 2 2 PXI Software Specification Revision 2 2 IEEE 1101 1 1991 IEEE Standard for Mechanical Core Specifications for M...

Page 8: ...les hardware and switches are undamaged Inspect the inner chassis for any possible damage debris or detached components If damage appears to have been caused during shipment file a claim with the carr...

Page 9: ...nization features Note The PXI 1056 chassis only complies with the 32 bit 33 MHz operational specs of the PXI Hardware Specification The key features of the PXI 1056 include the following PXI and Comp...

Page 10: ...t for portability Front rack mount brackets and handles Chassis Description Figures 1 1 and 1 2 show the key features of the PXI 1056 chassis front and rear panels Figure 1 1 shows the front view of t...

Page 11: ...el kits are available from National Instruments Rear Rack Mount Kits A rear rack mount kit option is available for mounting the PXI 1056 chassis into a 19 in instrument cabinet 1 Fan Filter Cover 2 Po...

Page 12: ...Appendix B Pinouts for pinout information Note The PXI 1056 backplane is 32 bit PCI 64 bit CompactPCI cards will operate in 32 bit mode in this chassis The PXI 1056 backplane has 5 V V I O Refer to t...

Page 13: ...ocal bus is a daisy chained bus that connects each peripheral slot with adjacent peripheral slots refer to Figure 1 3 For example slot 2 s right local bus connects to slot 3 s left local bus and so on...

Page 14: ...ocal Bus Local Bus Local Bus Local Bus Local Bus Local Bus PXI Trigger Bus Segment 1 PCI Bus Segment 1 PXI Trigger Bus Segment 2 PCI Bus Segment 2 PXI Trigger Bus Segment 3 PCI Bus Segment 3 Star Trig...

Page 15: ...ser specified line and directional assignments can be configured through Measurement Automation Explorer MAX Dynamic routing of triggers automatic line assignments is supported through certain Nationa...

Page 16: ...equipment to minimize shock hazards Refer to the Connecting Safety Ground section for instructions on connecting safety ground Live Circuits Operating personnel and service personnel must not remove...

Page 17: ...dequate Clearance Apertures in the rear and along the left side of the chassis facilitate power supply and module cooling Air enters through a filter and fan inlet in the right rear of the chassis and...

Page 18: ...on the rear panel of the PXI 1056 Refer to Figure 1 2 Rear View of the PXI 1056 Chassis to locate the fan speed selector switch Select HIGH for maximum cooling performance recommended or AUTO for qui...

Page 19: ...earth safety ground If your power outlet does not have an appropriate ground connection you must connect the premise safety ground to the chassis grounding screw located on the rear panel Refer to Fig...

Page 20: ...Complete the following steps to install a controller 1 Plug in the PXI chassis before installing the controller The power cord grounds the chassis and protects it from electrical damage while you inst...

Page 21: ...he controller front panel to the chassis using the controller front panel mounting screws 4 Connect the keyboard mouse and monitor to the appropriate connectors Connect devices to ports as required by...

Page 22: ...sis slot by first placing the module card edges into the front module guides left and right as shown in Figure 2 4 Slide the module to the rear of the chassis making sure that the injector ejector han...

Page 23: ...is powered on and operating normally Front Panel LED Indicators Cautions Operating the PXI system outside of the specified temperature range may result in loss of data reduction of chassis life or dam...

Page 24: ...he chassis should not exceed 60 C Remote Voltage Temperature and Fan Monitoring The PXI 1056 chassis supports remote voltage temperature and fan monitoring through a RS 232 9 pin D sub connector locat...

Page 25: ...bles contain each available command in the set along with proper syntax and brief descriptions of their effects In each example the Command column lists each command that can be sent through the RS 23...

Page 26: ...LF Transmit temperature sensor 2 value T3 T3 XX CR LF Transmit temperature sensor 3 value ST ST T1 x CR LF Temperature sensor 1 x OK or FAIL ST T2 x CR LF Temperature sensor 2 x OK or FAIL ST T3 x CR...

Page 27: ...C Power supply Voltage of the 12VDC Power supply Voltage of the 12VDC Power supply Voltage of the 5 VDC VSB Power Supply V1 V1 X XXX CR LF Voltage of the 3 3VDC Power supply V2 V2 X XXX CR LF Voltage...

Page 28: ...ower supply status x OK or FAIL ST T1 x CR LF Temperature sensor 1 x OK or FAIL ST T2 x CR LF Temperature sensor 2 x OK or FAIL ST T3 x CR LF Temperature sensor 3 x OK or FAIL SV V1 x CR LF 3 3VDC sup...

Page 29: ...creates the pxisys ini file which defines the layout and parameters of your PXI system After installing the software on the NI Driver CD ROM the MAX icon will be present on the desktop The configurat...

Page 30: ...s entry to display the popup menu then select the appropriate controller model from the Identify As submenu 4 Click on the PXI System controller and the chassis or multiple chassis in a multi chassis...

Page 31: ...dynamically configured by programs such as NI DAQmx This prevents the instruments from double driving the trigger lines possibly damaging devices in the chassis In the default configuration trigger li...

Page 32: ...document the capabilities of their products The minimum documentation requirements are contained in ini files which consist of ASCII text System integrators configuration utilities and device drivers...

Page 33: ...is chapter is designed for use by qualified service personnel Read the Read Me First Safety and Radio Frequency Interference document included with your kit before attempting any procedures in this ch...

Page 34: ...s wipe with a cloth moistened in a mild soap solution Remove any soap residue by wiping with a cloth moistened with clear water Do not use abrasive compounds on any part of the chassis Cleaning and Re...

Page 35: ...the procedure described in the Connecting to Power Source section of Chapter 2 Installation and Configuration If any of the monitoring LEDs are not a steady green contact National Instruments 5 Verify...

Page 36: ...f the PXI 1056 Chassis but it can be used as a visual reference There are four screws evenly spaced along the left and right edges Installation Ensure that there is no visible damage to the new power...

Page 37: ...features of the chassis may be impaired This appendix contains specifications for the PXI 1056 chassis Electrical AC Input Input voltage range 100 240 VAC Operating voltage range1 90 264 VAC Input fre...

Page 38: ...ply that provides DC power to the CompactPCI PXI backplane DC Output DC current capacity IMP Load regulation Maximum ripple and noise 20 MHz bandwidth Caution Be sure to limit DC output to 500 W above...

Page 39: ...ooling Per slot cooling capacity Slot cooling capacity is 25 W with fan speed set to HIGH Slot airflow direction P1 to P2 bottom of module to top of module Module cooling System Forced air circulation...

Page 40: ...C Tick and FCC Part 15 Class A compliant Emissions EN 55011 Class A 10 m FCC Part 15A above 1 GHz Immunity Evaluated to EN 61326 1997 A2 2001 Table 1 Note For EMC compliance operate this device with s...

Page 41: ...ms pulse Nonoperational1 2 30 g half sine 11 ms pulse Operating location Indoor use Random vibration Operational1 3 5 to 500 Hz 0 31 gRMS Nonoperational1 3 5 to 500 Hz 2 46 gRMS Altitude 2 000 m Measu...

Page 42: ...UL 94 V 0 Recognized Backplane connectors Conforms to IEC 917 and IEC 1076 4 101 and are UL 94 V 0 rated 10 MHz System Reference Clock 10 MHz REF Maximum clock skew between slots 250 ps Built in 10 M...

Page 43: ...17 0 in Depth 457 2 mm 18 0 in Weight 11 kg 24 3 lbs Chassis materials Sheet Aluminum 5052 H32 3003 H14 and 6061 T6 Extruded Aluminum 6060 T6 Cold Rolled Steel PC ABS Santoprene Nylon Finish Conducti...

Page 44: ...Appendix A Specifications NI PXI 1056 User Manual A 8 ni com Figure A 1 PXI 1056 Dimensions Front and Side in Inches mm 17 00 431 8 6 98 177 4 57 14 5 18 00 457 2 1 68 42 7 98 24 9 2 29 58 2...

Page 45: ...Appendix A Specifications National Instruments Corporation A 9 NI PXI 1056 User Manual Figure A 2 PXI 1056 Dimensions Bottom in Inches mm 16 06 407 9 74 18 8 85 21 6 15 28 388 1...

Page 46: ...endix A Specifications NI PXI 1056 User Manual A 10 ni com Figure A 3 shows the PXI 1056 rack mount kit components Figure A 3 PXI 1056 Rack Mount Components 1 PXI 1056 Chassis 2 Rack Mount Brackets 2...

Page 47: ...roller slot Table B 3 shows the P1 J1 connector pinout for the star trigger slot Table B 4 shows the P2 J2 connector pinout for the star trigger slot Table B 5 shows the P1 J1 connector pinout for the...

Page 48: ...AD 13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD...

Page 49: ...GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND FAL REQ5 GNT5 GND 14 GND BP I O BP I O BP I O GND BP I O GND 13 GND BP I O GND V I O BP I O BP I O GND 12 GND BP I O BP I O BP I O GND BP I O GND 11 GND BP I O...

Page 50: ...13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BD_SEL TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD...

Page 51: ...10_IN PXI_CLK10 GND 16 GND PXI_TRIG1 PXI_TRIG0 RSV GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND RSV PXI_STAR6 PXI_LBR6 GND 14 GND RSV RSV RSV GND RSV GND 13 GND RSV GND V I O RSV RSV GND 12 GND RSV RSV RS...

Page 52: ...AD 13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BD_SEL TRDY GND 12 14 Key Area 11 GND AD 18 AD 17...

Page 53: ...PXI_STAR PXI_CLK10 GND 16 GND PXI_TRIG1 PXI_TRIG0 RSV GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND RSV PXI_LBL6 PXI_LBR6 GND 14 GND RSV RSV RSV GND RSV GND 13 GND RSV GND V I O RSV RSV GND 12 GND RSV RSV...

Page 54: ...nstruments Application Engineers make sure every question receives an answer For information about other technical support options in your area visit ni com services or contact your local office at ni...

Page 55: ...m calibration If you searched ni com and could not find the answers you need contact your local office or NI corporate headquarters Phone numbers for our worldwide offices are listed at the front of t...

Page 56: ...co 10 12 n nano 10 9 micro 10 6 m milli 10 3 k kilo 103 M mega 106 G giga 109 T tera 1012 Symbols Degrees Equal or greater than Equal or less than Percent Ohms A A Amperes AC Alternating current ANSI...

Page 57: ...iring a more robust mechanical form factor than desktop PCI It uses industry standard mechanical components and high performance connector technologies to provide an optimized system intended for rugg...

Page 58: ...bitration for data transfers across the backplane Installing such a device into any other slot can damage the device the PXI backplane or both EMC Electromagnetic Compatibility EMI Electromagnetic Int...

Page 59: ...apid variations in clock transition times from their nominal regular intervals Units seconds RMS K kg Kilograms km Kilometers L lb Pounds LED Light emitting diode line regulation The maximum steady st...

Page 60: ...rers Association NI National Instruments NI DAQmx National Instruments driver which controls the operation of National Instruments data acquisition DAQ devices NI VISA National Instruments implementat...

Page 61: ...s is still connected to AC power mains star trigger slot This slot is located at slot 2 and has a dedicated trigger line between each peripheral slot Use this slot for a module with ST functionality t...

Page 62: ...National Instruments Corporation G 7 NI PXI 1056 User Manual T TTL Transistor transistor logic U UL Underwriter s Laboratories V V Volts VAC Volts alternating current or Vrms Vpp Peak to peak voltage...

Page 63: ...ii drivers NI resources C 1 D sub connector pinout table 2 9 E electromagnetic compatibility A 4 EMC filler panel kit 1 4 examples NI resources C 1 F fan speed measurement commands 2 11 filler panel i...

Page 64: ...nnector peripheral slot table B 7 star trigger slot table B 5 system controller slot table B 3 power cables table 1 2 power supply connecting to 2 4 remote voltage monitoring and inhibiting connector...

Page 65: ...ources C 1 specifications chassis cooling A 3 dimensions figure A 8 A 9 electrical AC input A 1 DC output A 2 electromagnetic compatibility A 4 environmental A 5 mechanical A 7 rack mount kit dimensio...

Reviews: