Appendix A
Specifications
©
National Instruments Corporation
A-7
Physical
Dimensions
(not including connectors) .................... 16.0 by 10.0 cm (6.3 by 3.9 in.)
I/O connectors
NI PXI-7831R................................. Three 68-pin female high-density
VHDCI type
Maximum Working Voltage
Maximum working voltage refers to the signal voltage plus the
common-mode voltage.
Channel-to-earth..................................... ±12 V, Installation Category I
Channel-to-channel ................................ ±24 V, Installation Category I
Environmental
Operating temperature............................ – 40 to 70
°C
Storage temperature ............................... –55 to 85 °C
Humidity ................................................ 10 to 90% RH, noncondensing
Maximum altitude .................................. 2,000 meters
Pollution Degree (indoor use only) ........ 2
Safety
The NI PXI-7831R devices meet the requirements of the following
standards for safety and electrical equipment for measurement, control, and
laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 3111-1
•
CAN/CSA C22.2 No. 1010.1
Note
For UL and other safety certifications, refer to the product label or to
ni.com
.