background image

©

 National Instruments Corporation

3

NI PXIe-1062Q Power Supply Shuttle User Guide

Figure 1.  

Rear View of the NI PXIe-1062Q Chassis

Installation and Maintenance

The information in this section is for qualified service personnel only. Read 
the 

Read Me First: Safety and Radio-Frequency Interference 

document 

included with your kit before using the power supply shuttle.

Caution

Many components within the NI PXIe-1062Q chassis under repair are susceptible 

to static discharge damage. Service the chassis only in a static-free environment. Observe 
standard handling precautions for static-sensitive devices while servicing the chassis. 
Always wear a grounded wrist strap, or equivalent, while servicing the chassis.

Caution

Always disconnect the AC power cable before cleaning or servicing the chassis.

1

Power Supply Shuttle

2

Push-Reset Circuit Breaker

3

Universal AC Input

4

Chassis Ground Screw

5

10  MHz  REF  OUT  BNC

6

10 MHz REF IN BNC

7

Remote Inhibit and Voltage Monitoring Connector

8

Air Filter Retainer

9

Air Filter Retainer Screw

10 Power Supply Shuttle ID Label
11 Fan Speed Selector Switch
12 Inhibit Mode Selector Switch
13 Power Supply Shuttle Handle (2x)
14 Power Supply Shuttle Mounting Screws (8x)

2

3

9

7

14

13

1

8

5

6

4

10

11

12

Summary of Contents for NI PXIe-1062Q

Page 1: ...ging Over current protection via push reset circuit breaker Remote power monitoring and inhibit via a rear panel connector Temperature sensing module that can adjust fan speed based on air intake temp...

Page 2: ...nit being repaired NI PXIe 1062Q power supply shuttle Read Me First Safety and Radio Frequency Interference NI PXIe 1062Q User Manual provided with the chassis also available at ni com support 1 Phill...

Page 3: ...ree environment Observe standard handling precautions for static sensitive devices while servicing the chassis Always wear a grounded wrist strap or equivalent while servicing the chassis Caution Alwa...

Page 4: ...on the back of the chassis Identify the eight mounting screws that attach the power supply shuttle to the chassis Refer to Figure 1 for the mounting screw locations Using a Phillips screwdriver remove...

Page 5: ...g screw Refer to Figure 1 to locate the chassis grounding screw To connect the safety ground complete the following steps 1 Connect a 16 AWG 1 3 mm wire to the chassis grounding screw using a groundin...

Page 6: ...ply to provide DC power to the CompactPCI PXI backplane DC Output DC current capacity IMP Notes Maximum combined 3 3 V 5 V and 12 V power is 345 W Maximum total power is 353 6 W The maximum power diss...

Page 7: ...V Clamped at 26 to 29 V difference between 12 and 12 V outputs Power supply shuttle MTTR Replacement in under 5 minutes Slot 5 V V I O 3 3 V 12 V 12 V 5 VAUX System Controller Slot 9 A 0 A 9 A 11 A 0...

Page 8: ...nal Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the...

Reviews: