National Instruments Corporation
23
NI sbRIO-961x/9612XT/963x/9632XT/964x/9642XT
Resetting the Network Configuration of the
NI sbRIO Device
If the NI sbRIO device is not able to communicate with the network, you
can use the IP RESET switch to manually restore the device to the factory
network settings. When you restore the device to the factory network
settings, the IP address, subnet mask, DNS address, gateway, and Time
Server IP are set to
0.0.0.0
. Power-on defaults, watchdog settings, and
VIs are unaffected.
Complete the following steps to restore the device to the factory network
settings.
1.
Move the IP RESET DIP switch to the ON position.
2.
Press the Reset button.
3.
Move the IP RESET switch to the OFF position.
The network settings are restored. You can reconfigure the settings in MAX
from a computer on the same subnet. Refer to the
Measurement &
Automation Explorer Help
for more information about configuring the
device.
Note
If the device is restored to the factory network settings, the LabVIEW run-time
engine does not load. You must reconfigure the network settings and reboot the device for
the LabVIEW run-time engine to load.