Chapter 2
Power and I/O
©
National Instruments Corporation
2-5
NI 17xx Smart Camera User Manual
The isolated outputs can be used to drive external loads, as shown in
Figures 2-3 and 2-4.
Figure 2-3.
Connecting an Isolated Output to a Sourcing External Load
Figure 2-4.
Connecting an Isolated Output to a Sinking External Load
S
o
u
rcing
Lo
a
d
I
s
oO
u
t+
I
s
oO
u
t–
NI 17xx
S
en
s
or
Power
S
en
s
or
Common
I
s
oO
u
t+
I
s
oO
u
t–
NI 17xx
S
en
s
or
Power
S
en
s
or
Common
S
inking
Lo
a
d