Appendix B
Troubleshooting
NI 17xx Smart Camera User Manual
B-6
ni.com
•
Make sure that you have enabled the corresponding external lighting
strobe in MAX or Vision Builder AI. Complete one of the following
procedures to enable the correct lighting strobe.
MAX
1.
Launch MAX.
2.
In the Configuration tree, expand
Devices and Interfaces
.
3.
Expand
NI-IMAQ Devices
.
4.
Expand the smart camera you are using.
5.
Select the channel you are using.
6.
Select the
Lighting
tab.
7.
Select the appropriate strobe from the
External
Strobe Generation
control.
Vision Builder AI
1.
Launch Vision Builder AI.
2.
In the
Acquire Image (Smart Camera)
step, select the
Lighting
tab.
3.
Select the appropriate strobe from the
External
Strobe Generation
control.
Triggering Problems
No Trigger is Received
If you are not receiving a trigger, verify the following:
•
The trigger is wired to the /IsoIn(0)+ and TrigIn–/IsoIn(0)–
signals.
•
If TrigIn/IsoIn(0) and IsoIn(1) are both being used, that the devices
they are connected to are either both sinking (NPN) or both sourcing
(PNP).
•
The trigger is connected correctly based on the type of sensor it
is—sourcing or sinking. Refer to the
section of
Chapter 2,
, for information about connecting isolated
inputs.
•
The sensor power supply is of appropriate voltage for interfacing to
NI Smart Camera isolated inputs. Refer to the
section
of Chapter 2,
, for information about isolated inputs.
Refer to Appendix A,
, for complete specifications.