ni.com
|
NI-XNET CAN HS/FD Transceiver Cable Instructions
Caution
Do
not
unplug transceiver cable unless power
has been switched off or the area is known to be
nonhazardous.
Caution
Substitution of components may impair
suitability for Class I, Division 2.
Caution
For Division 2 and Zone 2 applications, install
the system in an enclosure rated to at least IP 54 as
defined by IEC 60529 and EN 60529.
Caution
For Division 2 and Zone 2 applications, install
a protection device between the CAN bus and the
NI-XNET CAN HS/FD Transceiver Cable CAN pins.
The device must prevent the CAN Port-to-COM voltage
from exceeding 55 V if there is a transient overvoltage
condition.
Special Conditions for Safe Use in Europe
This equipment has been evaluated as Ex nA IIC T4 equipment
under DEMKO Certificate 12 ATEX Number (1202658X). Each
transceiver cable is marked
II 3G and is suitable for use in
Zone 2 hazardous locations.