background image

© 2014 National Instruments. All rights reserved.

374814B-01

Oct14

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National 

Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of 
their respective companies. For patents covering National Instruments products/technology, refer to the appropriate 
location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patent 

Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and 

third-party legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 for the National Instruments global trade compliance policy and 

how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED 
WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR 
ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense 
and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, 
DFAR 252.227-7014, and DFAR 252.227-7015.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world. For 
telephone support in the United States, create your service request 
at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). For 

telephone support outside the United States, visit the Worldwide 
Offices section of 

ni.com/niglobal

 to access the branch office 

websites, which provide up-to-date contact information, support 
phone numbers, email addresses, and current events.

Summary of Contents for NI-XNET LIN

Page 1: ...OPERATING INSTRUCTIONS NI XNET LIN Transceiver Cable...

Page 2: ...ni com downloads Note The safety guidelines and specifications in this document are specific to the NI XNET LIN Transceiver Cable The other components in your system may not meet the same safety ratin...

Page 3: ...truments for repair Safety Guidelines for Hazardous Locations The NI XNET LIN Transceiver Cable is suitable for use in Class I Division 2 Groups A B C D T4 hazardous locations Class I Zone 2 AEx nA II...

Page 4: ...least IP 54 as defined by IEC 60529 and EN 60529 Caution For Division 2 and Zone 2 applications install a protection device between the LIN bus and the NI XNET LIN Transceiver Cable LIN pins The devic...

Page 5: ...n environment of not more than Pollution Degree 2 Caution The enclosure must have a door or cover accessible only by the use of a tool Mounting the NI XNET LIN Transceiver Cable Caution The NI XNET LI...

Page 6: ...ions The NI XNET LIN Transceiver Cable has one 9 pin male D Sub connector that provides connections to a LIN bus The port has two common pins COM that are internally connected to the transceiver cable...

Page 7: ...uires an external power supply of 8 to 18 V to operate Supply power to the NI XNET LIN Transceiver Cable Vsup pin from the LIN bus The NI XNET LIN Transceiver Cable pinout is listed in Table 1 Table 1...

Page 8: ...et the physical medium requirement of a bus RC time constant of 5 s For detailed formulas for calculating this value refer to the Line Characteristics section of the LIN specification Belden cable 308...

Page 9: ...r node requires a 1 k resistor and serial diode between the LIN bus and Vsup On NI XNET LIN products master termination is software selectable you can enable it in the API with the NI XNET Session Int...

Page 10: ...connector To connect the NI XNET LIN Transceiver Cable to a host device push the connector assembly into the host receptacle until the internal latch snaps into position The latch emits an audible cl...

Page 11: ...NI XNET Transceiver Cables include two LEDs per port to help you monitor hardware and bus status LED 1 primarily indicates whether the hardware is currently in use LED 2 primarily indicates the activi...

Page 12: ...a constant rate of several times per second Activity Blinks in a pseudo random pattern Table 3 LED Pattern Indications Condition State LED 1 LED 2 Port identification Blinks green Blinks green NI XNE...

Page 13: ...unless otherwise noted LIN Characteristics Transceiver NXP TJA1028 Max baud rate 20 kbps LIN bus lines voltage 40 to 40 VDC Open session on hardware port is missing power Solid red Off Hardware is com...

Page 14: ...F or MIL HDBK 217F specifications Power Requirements Thermal dissipation at 70 C 650 mW max active mode 330 mW typical active mode Power consumption from NI XNET Transceiver Cable host 330 mW max acti...

Page 15: ...zardous live electrical supply system that powers equipment This category is for measurements of voltages from specially protected secondary circuits Such voltage measurements include signal levels sp...

Page 16: ...CAT IV Isolation Voltage Port to earth ground Continuous 60 VDC Measurement Category I Note The NI XNET LIN Transceiver Cable COM signals are not connected to the host port ground This isolation is in...

Page 17: ...60079 15 Ed 3 CSA 60079 0 2011 CSA 60079 15 2012 Note For UL and other safety certifications refer to the product label or the Online Product Certification section Hazardous Locations U S UL Class I...

Page 18: ...1 IEC 60068 2 2 401 to 70 C Storage temperature IEC 60068 2 1 IEC 60068 2 2 401 to 85 C Ingress protection IP 40 Operating humidity IEC 60068 2 56 10 to 90 RH noncondensing Storage humidity IEC 60068...

Page 19: ...transceiver cable and ensure all cables and connectors have proper strain relief Operating vibration random IEC 60068 2 64 5 grms 10 to 500 Hz Operating shock IEC 60068 2 27 30 g 11 ms half sine 50 g...

Page 20: ...d laboratory use EN 61326 IEC 61326 Class A emissions Basic immunity EN 55011 CISPR 11 Group 1 Class A emissions AS NZS CISPR 11 Group 1 Class A emissions FCC 47 CFR Part 15B Class A emissions ICES 00...

Page 21: ...cation Refer to the product Declaration of Conformity DoC for additional regulatory compliance information To obtain product certifications and the DoC for this product visit ni com certification sear...

Page 22: ...this document Waste Electrical and Electronic Equipment WEEE EU Customers At the end of the product life cycle all products must be sent to a WEEE recycling center For more information about WEEE recy...

Page 23: ...and other services Visit ni com register to register your National Instruments product Product registration facilitates technical support and ensures that you receive important information updates fr...

Page 24: ...icy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR...

Reviews: