background image

Appendix A

Specifications

NI PXI-1036/PXI-1036DC User Manual

A-4

ni.com

Shock and Vibration

Operational shock ...................................30 g peak, half-sine, 11 ms pulse 

(Tested in accordance with 
IEC-60068-2-27. Test profile 
developed in accordance with 
MIL-PRF-28800F.)

Random Vibration

Operating ................................................5 to 500 Hz, 0.3 g

rms

Nonoperating ..........................................5 to 500 Hz, 2.4 g

rms

(Tested in accordance with 
IEC-60068-2-64. Nonoperating 
test profile exceeds the 
requirements of 
MIL-PRF-28800F, Class 3.)

Acoustic Emissions

Sound Pressure Level (at Operator Position)

Tested in accordance with ISO 7779.

PXI-1036

Auto fan (at 25 °C ambient) ............35.0 dBA

High fan ...........................................51.1 dBA

Sound Power

Tested in accordance with ISO 7779.

PXI-1036

Auto fan (at 25 °C ambient) ............43.4 dBA

High fan ...........................................59.5 dBA

Summary of Contents for PXI-1036DC

Page 1: ...PXI NI PXI 1036 PXI 1036DC User Manual NI PXI 1036 PXI 1036DC User Manual December 2010 371550E 01...

Page 2: ...banon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 328 90 10 Portugal 351 210 311 210 Russia...

Page 3: ...n information retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation National Instruments respects the intellectual property of other...

Page 4: ...36DC Backplane Overview 1 6 Interoperability with CompactPCI 1 6 System Controller Slot 1 7 Star Trigger Slot 1 7 Peripheral Slots 1 7 Local Bus 1 7 Trigger Bus 1 8 System Reference Clock 1 8 Chapter...

Page 5: ...gger Configuration in MAX 2 11 Using System Configuration and Initialization Files 2 12 Chapter 3 Maintenance DC Fuse Replacement PXI 1036DC Only 3 1 Service Interval 3 1 Preparation 3 1 Cleaning 3 2...

Page 6: ...ata loss or a system crash When this symbol is marked on the product refer to the Read Me First Safety and Electromagnetic Compatibility document shipped with the product for precautions to take bold...

Page 7: ...NI PXI 1031DC 1036DC DC Cable Kit Installation Guide CompactPCI Specification PICMG 2 0 R 3 0 PXI Hardware Specification PXI Software Specification IEEE 1101 1 1991 IEEE Standard for Mechanical Core S...

Page 8: ...hardware and switches are undamaged Inspect the inner chassis for any possible damage debris or detached components If damage appears to have been caused during shipment file a claim with the carrier...

Page 9: ...ty in a wide range of applications The key features of the chassis include the following Accepts 3U PXI and CompactPCI PICMG 2 0 R 3 0 modules 6 slot chassis with universal AC input and automatic volt...

Page 10: ...xcept for the chassis name stenciled on the face plate Figure 1 2 shows the rear view of the PXI 1036 Figure 1 3 shows the rear panel of the PXI 1036DC Figure 1 4 shows the bottom of the chassis both...

Page 11: ...PXI 1036DC Chassis 1 Rear Exhaust Vents 2 AC Input 3 Power Supply Fan Exhaust 4 Chassis Ground Screw 5 AUTO HIGH Fan Speed Selector Switch 6 Rubber Foot 1 Rear Exhaust Vents 2 DC Fuse Socket 3 DC Inp...

Page 12: ...XI 1036DC chassis EMC Filler Panels Optional EMC filler panel kits are available from National Instruments Rack Mount Kits A rack mount kit option is available for mounting the PXI 1036 or PXI 1036DC...

Page 13: ...nt feature because some PXI systems may require components that do not implement PXI specific features For example you may want to use a standard CompactPCI network interface card in a PXI chassis The...

Page 14: ...eripheral module in this slot The star trigger slot can also be used to provide a PXI_CLK10 signal to the backplane For more information regarding PXI_CLK10 refer to the System Reference Clock section...

Page 15: ...PXI 10 MHz system clock signal PXI_CLK10 independently to each peripheral slot An independent buffer having a source impedance matched to the backplane and a skew of less than 250 ps between slots dri...

Page 16: ...e of this equipment to minimize shock hazards Refer to the Connecting Safety Ground section for instructions on connecting safety ground Live Circuits Operating personnel and service personnel must no...

Page 17: ...odule cooling Air enters through the fan inlet in the bottom of the chassis for module cooling It then exits through the upper sections at the right side back and through the top as shown in Figure 2...

Page 18: ...and PXI 1036DC Refer to Figure 1 2 Rear View of the PXI 1036 Chassis or Figure 1 3 Rear View of the PXI 1036DC Chassis to locate the fan speed selector switch Select HIGH for maximum cooling performan...

Page 19: ...afety ground For DC powered applications or if your power outlet does not have an appropriate ground connection you must connect the premise safety ground to the chassis grounding screw located on the...

Page 20: ...nnecting to a DC Power Source PXI 1036DC Only For full chassis power the DC source must be capable of providing a minimum of 300 watts of continuous power per feed pair to the P1 connector on the PXI...

Page 21: ...om National Instruments that incorporates an in line fuse and the mating connector for the P1 port Installing a PXI Controller This section contains general instructions for installing a PXI controlle...

Page 22: ...as shown in Figure 2 3 Figure 2 3 Injector Ejector Handle Position during Controller or Peripheral Module Insertion 3 When you begin to feel resistance push up on the injector ejector handle to inject...

Page 23: ...036DC Chassis Installing PXI Modules Complete the following steps to install a module 1 Make sure the power switch is in the Off Standby position 2 Install a module into a chassis slot by first placin...

Page 24: ...p on the injector ejector handle to fully inject the module into the chassis frame Secure the module front panel to the chassis using the module front panel mounting screws Figure 2 5 Installing PXI o...

Page 25: ...NI Driver CD ROM the MAX icon will be present on the desktop The configuration steps for single or multiple chassis systems are the same Figure 2 6 Chassis Configuration in MAX Basic PXI System Confi...

Page 26: ...ger Configuration in MAX Each chassis has one or more trigger buses each with eight lines numbered 0 through 7 that can be reserved and routed statically or dynamically Static reservation pre allocate...

Page 27: ...e media that comes with the chassis The information in this file is combined with information about the system controller to create a single system initialization file called pxisys ini PXI System Ini...

Page 28: ...e the fuse pull straight out from the chassis Service Interval Clean dust from the chassis exterior and interior as needed based on the operating environment Periodic cleaning increases reliability Pr...

Page 29: ...round components Exterior Cleaning Cautions Avoid getting moisture inside the chassis during exterior cleaning especially through the top vents Use just enough moisture to dampen the cloth Do not wash...

Page 30: ...ns for the PXI 1036 and PXI 1036DC chassis PXI 1036 Chassis Electrical Caution Overloading the circuits may damage supply wiring Do not exceed the ratings on the equipment nameplate when connecting eq...

Page 31: ...ent protection All outputs protected from short circuit and overload Over voltage protection Chassis Cooling Per slot cooling capacity 25 W Slot airflow direction P1 to P2 bottom of module to top of m...

Page 32: ...perating location Indoor use Maximum altitude 2 000 m Measurement Category II Pollution Degree 2 Operating Environment Ambient temperature range 0 to 50 C Tested in accordance with IEC 60068 2 1 and I...

Page 33: ...tion Operating 5 to 500 Hz 0 3 grms Nonoperating 5 to 500 Hz 2 4 grms Tested in accordance with IEC 60068 2 64 Nonoperating test profile exceeds the requirements of MIL PRF 28800F Class 3 Acoustic Emi...

Page 34: ...e1 90 264 VAC Input frequency 50 60 Hz Operating frequency range1 47 63 Hz Input current rating 4 2 A Over current protection 6 3 A fuse in power supply no user serviceable components inside chassis E...

Page 35: ...derated 5 W C above 45 C The combined loading on 5 VDC and 3 3 VDC must not exceed 112 W For AC powered applications the combined loading must not exceed 145 6 W Overcurrent protection All outputs pro...

Page 36: ...circulation through integrated fan Intake Front and left side of chassis Exhaust Rear side of chassis Environmental Operating location Indoor use Maximum altitude 2 000 m Measurement Category II Poll...

Page 37: ...cordance with MIL PRF 28800F Random Vibration Operating 5 to 500 Hz 0 3 grms Nonoperating 5 to 500 Hz 2 4 grms Tested in accordance with IEC 60068 2 64 Nonoperating test profile exceeds the requiremen...

Page 38: ...the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 IEC 61326 Class A emissions Basic immunity EN 55011 CISPR 11 Group 1 Class A emissions AS NZS C...

Page 39: ...ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document Waste Electrical and...

Page 40: ...ranteed over the operating temperature range Mechanical Overall dimensions standard chassis Height 177 mm 6 97 in Note 12 7 mm 0 50 in is added to height when feet are installed Width 257 1 mm 10 12 i...

Page 41: ...A 3 Notice that the front and rear rack mounting holes size M4 are symmetrical Figure A 1 PXI 1036 PXI 1036DC Dimensions Front and Side in Inches mm 10 12 in 257 1 mm 0 50 in 12 7 mm 6 97 in 177 mm 0...

Page 42: ...ecifications National Instruments Corporation A 13 NI PXI 1036 PXI 1036DC User Manual Figure A 2 PXI 1036 PXI 1036DC Dimensions Bottom in Inches mm 8 74 in 222 mm 0 69 in 17 5 mm 6 49 in 164 85 mm 0 8...

Page 43: ...XI 1036 PXI 1036DC User Manual A 14 ni com Figure A 3 shows the PXI 1036 PXI 1036DC rack mount kit components Figure A 3 PXI 1036 PXI 1036DC Rack Mount Kit Components 1 PXI 1036 PXI 1036DC Chassis 2 R...

Page 44: ...ut for the System Controller slot Table B 2 shows the P2 J2 connector pinout for the System Controller slot Table B 3 shows the P1 J1 connector pinout for the star trigger slot Table B 4 shows the P2...

Page 45: ...GND AD 13 GND 18 GND SERR GND 3 3 V PAR C BE 1 GND 17 GND 3 3 V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3 V FRAME IRDY GND TRDY GND 12 14 Key Area 11 GND AD 18 A...

Page 46: ...DEG GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND FAL REQ5 GNT5 GND 14 GND BP I O BP I O BP I O GND BP I O GND 13 GND BP I O GND V I O BP I O BP I O GND 12 GND BP I O BP I O BP I O GND BP I O GND 11 GND B...

Page 47: ...D AD 13 GND 18 GND SERR GND 3 3 V PAR C BE 1 GND 17 GND 3 3 V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3 V FRAME IRDY BD_SEL TRDY GND 12 14 Key Area 11 GND AD 18 A...

Page 48: ...I_CLK10_IN PXI_CLK10 GND 16 GND PXI_TRIG1 PXI_TRIG0 RSV GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND RSV PXI_STAR6 PXI_LBR6 GND 14 GND RSV RSV RSV GND RSV GND 13 GND RSV GND V I O RSV RSV GND 12 GND RSV R...

Page 49: ...ND AD 13 GND 18 GND SERR GND 3 3 V PAR C BE 1 GND 17 GND 3 3 V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3 V FRAME IRDY BD_SEL TRDY GND 12 14 Key Area 11 GND AD 18...

Page 50: ...ND RSV PXI_STAR PXI_CLK10 GND 16 GND PXI_TRIG1 PXI_TRIG0 RSV GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND RSV PXI_LBL6 PXI_LBR6 GND 14 GND RSV RSV RSV GND RSV GND 13 GND RSV GND V I O RSV RSV GND 12 GND R...

Page 51: ...ndard Service Program Membership This program entitles members to direct access to NI Applications Engineers via phone and email for one to one technical support as well as exclusive access to on dema...

Page 52: ...product by visiting ni com certification Calibration Certificate If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration If you searched...

Page 53: ...e p pico 10 12 n nano 10 9 micro 10 6 m milli 10 3 k kilo 103 M mega 106 G giga 109 T tera 1012 Symbols Degrees Equal or greater than Equal or less than Percent Ohms A A Amperes AC Alternating current...

Page 54: ...CI It uses industry standard mechanical components and high performance connector technologies to provide an optimized system intended for rugged applications It is electrically compatible with the PC...

Page 55: ...agnetic Compatibility EMI Electromagnetic Interference F FCC Federal Communications Commission filler panel A blank module front panel used to fill empty slots in the chassis G g 1 grams 2 a measure o...

Page 56: ...egulation The maximum steady state percentage that a DC voltage output will change as a result of a step change from no load to full load output current M m Meters MAX NI Measurement Automation Explor...

Page 57: ...Nanosecond one billionth of a second 10 9 P ppm Parts per million PXI PCI eXtensions for Instrumentation PXI is an implementation of CompactPCI with added electrical features that meet the high perfor...

Page 58: ...pherals system reference clock A 10 MHz clock also called PXI_CLK10 that is distributed to all peripheral slots in the chassis The system reference clock can be used for synchronization of multiple mo...

Page 59: ...kplane 1 6 configuration See installation configuration and operation conventions used in the manual vii cooling air cooling of PXI 1036 2 2 air cooling of PXI 1036DC 2 2 air intake figure 2 3 filler...

Page 60: ...vers NI resources C 1 interoperability with CompactPCI 1 6 K key features 1 2 KnowledgeBase C 1 L local bus routing 1 7 star trigger and local bus routing figure 1 8 M maintenance of PXI 1036 cleaning...

Page 61: ...ar trigger ST slot 1 7 system reference clock 1 8 trigger bus 1 8 bottom view of chassis 1 5 EMC filler panel kit 1 5 fan speed setting 2 3 front view figure 1 3 handle feet kit 1 5 installation See i...

Page 62: ...onmental A 3 shock and vibration A 4 specifications PXI 1036DC acoustic emissions A 8 sound power A 8 sound pressure level at operator position A 8 chassis cooling A 6 electrical AC input A 5 DC input...