Interior Cleaning

Use a dry, low-velocity stream of air to clean the interior of the chassis. Use a soft-bristle
brush for cleaning around components.

Exterior Cleaning

Clean the exterior surfaces of the chassis with a dry, lint-free cloth or a soft-bristle brush. If
any dirt remains, wipe with a cloth moistened in a mild soap solution. Remove any soap
residue by wiping with a cloth moistened with clear water. Do not use abrasive compounds on
any part of the chassis.

Caution

 

Avoid getting moisture inside the chassis during exterior cleaning,

especially through the top vents. Use just enough moisture to dampen the cloth.
Do not wash the front- or rear-panel connectors or switches. Cover these
components while cleaning the chassis.

Do not use harsh chemical cleaning agents; they may damage the chassis. Avoid
chemicals that contain benzene, toluene, xylene, acetone, or similar solvents.

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for information about the services NI offers.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,
78759-3504. NI also has offices located around the world. For support in the United States,
create your service request at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). For

support outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/niglobal

 to

access the branch office websites, which provide up-to-date contact information.

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at 

ni.com/trademarks

 for

information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their
respective companies. For patents covering NI products/technology, refer to the appropriate location: 

Help

»

Patents in your

software, the 

patents.txt

 file on your media, or the National Instruments Patent Notice at 

ni.com/patents

. You can find

information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer
to the Export Compliance Information at 

ni.com/legal/export-compliance

 for the NI global trade compliance policy and how

to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS
TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.
Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2019 National Instruments. All rights reserved.

377738A-01

August 8, 2019

Summary of Contents for PXIe-1088

Page 1: ...System Controller Slot 6 Hybrid Peripheral Slots 6 PXI Local Bus 7 PXI Trigger Bus 8 System Reference Clock 8 Installation and Configuration 9 Safety Information 9 Chassis Cooling Considerations 10 R...

Page 2: ...to the metal work Check to make sure all handles hardware and switches are undamaged Inspect the inner chassis for any possible damage debris or detached components If damage appears to have been caus...

Page 3: ...B s or 2 GB s single direction per PXI Express slot dedicated bandwidth x1 or x4 Gen 2 PCI Express 3 hybrid peripheral slots connect as x4 links to the system slot 5 hybrid peripheral slots connect as...

Page 4: ...y features of the PXIe 1088 chassis front and back panels Figure 1 Front View of the PXIe 1088 PXIe 1088 LOW POWER 2 3 4 1 5 6 7 8 9 1 2 7 6 4 3 5 8 9 1 System Controller Expansion Slot 2 Backplane Co...

Page 5: ...MC Filler Panels EMC filler panel kits are available from National Instruments Slot Blockers PXI Slot Blocker kits are available from National Instruments for improved thermal performance when all slo...

Page 6: ...to peripheral slots as x4 links slots 4 6 and 8 The other system slot link is routed as a x4 link to the PCI Express switch providing x1 PCI Express links to the remaining peripheral slots and the two...

Page 7: ...Local Bus The hybrid peripheral slot connects to only PXI Local Bus 6 left and right Figure 3 PXIe 1088 PCI Express Backplane Diagram x4 x4 x4 x4 x1 x1 x1 x4 x4 x1 x1 x1 x1 x4 Port 15 Port 5 Port 7 P...

Page 8: ...ny trigger line may be routed in either direction it cannot be routed in more than one direction at a time Figure 4 PXI Trigger Bus Connectivity Diagram H H H 7 8 9 H H H H 1 2 3 4 5 6 PXI Trigger Bri...

Page 9: ...us to human life and safety and is capable of inflicting personal injury Chassis Grounding The chassis requires a connection from the premise wire safety ground to the chassis ground The earth safety...

Page 10: ...ection Providing Adequate Clearance The module and power supply intake vents are located on the front left side and bottom of the chassis The module and power supply exhaust vents for the PXIe 1088 ar...

Page 11: ...ck or benchtop use you can monitor the chassis intake temperatures in Measurement Automation Explorer MAX to ensure the temperatures do not exceed the ratings in the Operating Environment section of t...

Page 12: ...Definition The chassis fan control system uses ambient intake air temperatures for controlling fan speeds when in Auto mode These temperatures may be higher than ambient room temperature depending on...

Page 13: ...formance of the chassis can be improved by installing optional slot blockers Refer to the National Instruments website at ni com info and enter the Info Code slotblocker for more information about slo...

Page 14: ...riate earth safety ground If your power outlet does not have an appropriate ground connection you must connect the premise safety ground to the chassis grounding screw located on the rear panel To con...

Page 15: ...uctions for installing a PXI Express system controller in a PXIe 1088 chassis 1 Connect the AC power source to the PXI Express chassis before installing the system controller The AC power cord grounds...

Page 16: ...Refer to your peripheral module user manual for specific instructions and warnings To install a module complete the following steps 1 Connect the AC power source to the PXI Express chassis before inst...

Page 17: ...5 Injector Ejector Rail LED Indicator The following figure shows the front panel Status LED The following table describes the Status LED states Figure 11 Status LED Table 2 Front Panel Status LED Sta...

Page 18: ...off right position Default mode is selected When this switch is in the on left position Manual mode is selected Figure 12 Backplane DIP Switches 1 2 3 4 1 Switch 1 Fan 2 Switch 2 PWR 3 Switch 3 NC 4 S...

Page 19: ...on about the DIP switch Refer to the Front View of the PXIe 1088 Chassis for the location of this switch Fan Mode The PXIe 1088 chassis operates in two main fan modes In Auto mode the speed of the cha...

Page 20: ...automatically identifies your PXI Express system components to generate a pxiesys ini file You can configure your entire PXI system and identify PXI 1 chassis through Measurement Automation Explorer M...

Page 21: ...riant or firmware and platform services version Trigger Configuration in MAX PXI Platform Services provides an interface to route and reserve triggers so dynamic routing through drivers such as DAQmx...

Page 22: ...tic reservation of trigger lines can be implemented by the user in MAX through the Triggers tab PXI modules dynamically configured by programs such as NI DAQmx will not use reserved trigger lines This...

Page 23: ...Figure 14 Trigger Configuration in MAX PXIe 1088 User Guide National Instruments 23...

Page 24: ...se modes You may also select a Manual fan mode In this mode you may manually set the fan speeds to achieve the desired performance Note You may not set the fan speeds or power settings lower than the...

Page 25: ...enance procedures you can perform on the PXIe 1088 chassis Caution Disconnect the power cable prior to servicing your PXIe 1088 chassis Service Interval Clean dust from the chassis exterior and interi...

Page 26: ...at 11500 North Mopac Expressway Austin Texas 78759 3504 NI also has offices located around the world For support in the United States create your service request at ni com support or dial 1 866 ASK M...

Reviews: