background image

PXIe-4844 Installation Guide and Specifications

|

© National Instruments

|

3

What You Need to Get Started

LabVIEW 2009 (32-bit), 2010 (32-bit), 2011 (32-bit), 2012 (32-bit), 2013 (32-bit), 

2014 (32-bit), 2015 (32-bit), or 2016 (32-bit)

PXI Express chassis with

controller, 

or

MXI-Express (card or built-in)

FBG sensors

Multiplexer for additional channels (optional)

Installing the NI-OSI Driver Software

Install the NI-OSI driver software on the host computer 

before

 installing the PXIe-4844 module. 

Refer to 

readme_OSI.html

, located in the 

National Instruments\OSI Explorer

 

directory, for software installation instructions, LabVIEW compatibility information, and 

system requirements.

Installing the PXIe-4844

This section contains installation instructions for the PXIe-4844. Refer to your PXI Express 

chassis user manual for chassis instructions and warnings.
1. Plug in your chassis before installing the PXIe-4844. The power cord grounds the chassis 

and protects it from electrical damage while you install the module.

2. Make sure the chassis power switch is turned off.

Caution

To protect both yourself and the chassis from electrical hazards, leave the 

chassis powered off until you finish installing the PXIe-4844 module.

3. Touch a metal part on the chassis to discharge any static electricity that might be on your 

clothes or body.

Summary of Contents for PXIe-4844

Page 1: ...g a single optical fiber The PXIe 4844 requires no calibration as it continuously adjusts its measurements using an on board NIST traceable wavelength reference Caution This icon denotes a caution whi...

Page 2: ...les Caution To ensure the specified EMC performance operate this product only with shielded cables and accessories Caution To ensure the specified EMC performance when using the AUX port install a sna...

Page 3: ...ry for software installation instructions LabVIEW compatibility information and system requirements Installing the PXIe 4844 This section contains installation instructions for the PXIe 4844 Refer to...

Page 4: ...e left most slot must be one of the following PXI Express slots PXI Express Peripheral Slot a PXI Express slot marked with a solid circle containing the slot number PXI Express Hybrid Peripheral Slot...

Page 5: ...me into contact with adjacent modules Figure 2 Sliding the PXIe 4844 into the Chassis 10 Raise the injector ejector handle to latch the module into the chassis The front panel of the PXIe 4844 should...

Page 6: ...e the PXIe 4844 in its original antistatic bag Store the module within its hard shelled plastic case Connecting Sensors The PXIe 4844 has four simplex singlemode LC APC connector ports to connect sens...

Page 7: ...4844 Cleaning Sensors To clean the optical sensors use a ferrule cleaner or follow the standard guidelines 1 Fold a lint free wipe into a compress 2 Moisten the compress with isopropyl alcohol 3 Remov...

Page 8: ...I OSI Explorer to identify and configure the optical sensors connected to the PXIe 4844 Use the Optical Measurement VIs in LabVIEW to perform optical sensing measurements To get started 1 Select Start...

Page 9: ...and connectors visit ni com dimensions and search by module number Dimensions without connectors 13 1 cm 21 4 cm 4 1 cm 5 1 in 8 4 in 1 6 in Weight 213 g 7 5 oz I O connector LC APC Slot requirements...

Page 10: ...for measurement control and laboratory use IEC 60825 1 ED 2 0 2007 03 US CDRH 21 CFR Subchapter J CE Compliance This product meets the essential requirements of applicable European Directives as follo...

Page 11: ...s substances from our products is beneficial to the environment and to NI customers For additional environmental information refer to the Minimize Our Environmental Impact web page at ni com environme...

Page 12: ...ur complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Ap...

Reviews: