Store the device in the antistatic package when the device is not in use.

Other Equipment

Your application may require additional items not included in your kit to interact with your
device. The following accessories can connect to the PXIe-5172.

PXI Chassis Slot Blocker kit (NI part number 199198-01)

SMB (m)-to-SMB (m) cables

AUX 0 cable (SHH19-MH19-AUX, NI part number 784091-01)

AUX 0 accessory terminal block for connecting to external signals, including clocks or
digital resources (SCB-19, NI part number 783959-01)

To use probes with the PXIe-5172, NI recommends using a cable adaptor (SMB (f)-to-
BNC (f), NI part number 781449-01 for one adaptor, or NI part number 781449-10 for ten
adaptors). With an adaptor, you can use the following probes:

CP500X—500 MHz, 1.2 m, 10X Cable Divider Probe

CP400X—400 MHz, 2 m, 10X Cable Divider Probe

SP500X—500 MHz, 10x Passive Probe

SP500C—500 MHz, 100x Passive Probe

NI-5191—800 MHz, Differential Active Probe

SA1000X—1 GHz Single-Ended Active Probe

SA1500X—1.5 GHz Single-Ended Active Probe

SA2500X—2.5 GHz Single-Ended Active Probe

Preparing the Environment

Ensure the environment in which you are using the PXIe-5172 meets the following
specifications.

Operating environment

Ambient temperature range

0 °C to 45 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 low temperature
limit and MIL-PRF-28800F Class 4 high
temperature limit.)

Relative humidity range

10% to 90%, noncondensing (Tested in
accordance with IEC 60068-2-56.)

Maximum altitude

2,000 m (800 mbar) (at 25 °C ambient
temperature)

Pollution Degree

2

PXIe-5172 Getting Started Guide

  | 

© National Instruments

  | 

3

Summary of Contents for PXIe-5172

Page 1: ...user documentation Using the model in a manner not specified can damage the model and compromise the built in safety protection Return damaged models to NI for repair Attention Suivez toutes les instr...

Page 2: ...formation about minimum system requirements recommended system requirements and supported application development environments ADEs refer to the readme for your selected software support Readmes are a...

Page 3: ...the following probes CP500X 500 MHz 1 2 m 10X Cable Divider Probe CP400X 400 MHz 2 m 10X Cable Divider Probe SP500X 500 MHz 10x Passive Probe SP500C 500 MHz 100x Passive Probe NI 5191 800 MHz Differen...

Page 4: ...device FPGA to create application specific instrument designs Instrument design libraries with the LabVIEW FPGA Module Note You can use a combination of these software options for your application Ho...

Page 5: ...s connected to the chassis before installing the PXIe 5172 The AC power cord grounds the chassis and protects it from electrical damage while you install the PXIe 5172 2 Power off the chassis 3 Inspec...

Page 6: ...PXI Express system timing slots or PXI Express peripheral slots 8 Touch any metal part of the chassis to discharge static electricity 9 Place the module edges into the module guides at the top and bo...

Page 7: ...omagnetic performance 11 Cover all empty slots using EMC filler panels or fill using slot blockers to maximize cooling air flow depending on your application 12 Power on the chassis PXIe 5172 Front Pa...

Page 8: ...power output AUX 0 Connector Pinout 16 14 12 18 19 17 15 13 10 11 8 6 4 2 1 3 5 7 9 Table 3 AUX 0 Connector Pin Assignments Pin Signal Signal Description 1 GND Ground reference for signals 2 CLK IN U...

Page 9: ...PFI 5 Bidirectional PFI line 16 AUX 0 PFI 6 Bidirectional PFI line 17 AUX 0 PFI 7 Bidirectional PFI line 18 3 3 V 3 3 V power 200 mA maximum 19 GND Ground reference for signals PXIe 5172 SCB 19 Pinou...

Page 10: ...tomation Explorer MAX to configure your National Instruments hardware MAX informs other programs about which devices reside in the system and how they are configured MAX is automatically installed wit...

Page 11: ...The PXIe 5172 modules are externally calibrated at the factory however you should perform a self calibration in any of the following situations After first installing the PXIe 5172 into your chassis...

Page 12: ...with LabVIEW 1 Launch LabVIEW 2 Select Help Find Examples 3 Open the example VI that you want to use by selecting Hardware Input and Output Modular Instruments NI SCOPE High Speed Digitizers Tip If y...

Page 13: ...ction of the documentation 7 Follow the instructions in the project documentation for making the measurement Troubleshooting If an issue persists after you complete a troubleshooting procedure contact...

Page 14: ...or self calibration again Where To Go Next Refer to the following resources and information that you may need as you create your own application EXPLORE LEARN CREATE DISCOVER custom applications withi...

Page 15: ...ct registration facilitates technical support and ensures that you receive important information updates from NI NI corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759...

Page 16: ...s EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and...

Reviews: