background image

Figure 2.

 Chassis Compatibility Symbols

NI PXIe-1062Q

1

2

3

4

5

1. PXI Express System Controller Slot
2. PXI Peripheral Slot
3. PXI Express Hybrid Peripheral Slot

4. PXI Express System Timing Slot
5. PXI Express Peripheral Slot

6.

Touch any metal part of the chassis to discharge static electricity.

7.

Ensure that the ejector handle is in the unlatched (downward) position.

8.

Place the module edges into the module guides at the top and bottom of the chassis. Slide
the device into the slot until it is fully inserted.

Figure 3.

 Module Installation

NI PXIe-1075

2

3

1

1. Chassis
2. Hardware Module
3. Ejector Handle in Down (Unlatched) Position

9.

Latch the module in place by pulling up on the ejector handle.

10. Secure the device front panel to the chassis using the front-panel mounting screws.

Note

 

Tightening the top and bottom mounting screws increases mechanical

stability and also electrically connects the front panel to the chassis, which can
improve the signal quality and electromagnetic performance.

11. Cover all empty slots using filler panels or slot blockers to maximize cooling air flow.
12. Power on the chassis.

NI PXIe-5622 Getting Started Guide

  | 

© National Instruments

  | 

5

Summary of Contents for PXIe-5622

Page 1: ...nt 3 Preparing the Environment 3 Installing the Software 4 Installing the NI 5622 4 Hardware Front Panel Connectors 6 Configuring the Hardware in MAX 7 Programming the NI 5622 8 Troubleshooting 9 Why...

Page 2: ...cables must be no longer than 30 m 100 ft Verifying the System Requirements To use the NI 5622 your system must meet certain requirements For more information about minimum system requirements recomm...

Page 3: ...n are required for installation and operation of the NI 5622 Preparing the Environment Ensure that the environment in which you are using the NI 5622 meets the following specifications Operating Envir...

Page 4: ...Accept the prompts to complete the installation 4 When the installer completes select Restart in the dialog box that prompts you to restart shut down or restart later Installing the NI 5622 Caution T...

Page 5: ...til it is fully inserted Figure 3 Module Installation NI PXIe 1075 2 3 1 1 Chassis 2 Hardware Module 3 Ejector Handle in Down Unlatched Position 9 Latch the module in place by pulling up on the ejecto...

Page 6: ...ACTIVE PFI 1 IF IN CLK IN CLK OUT TTL 5 V MAX Table 1 NI 5622 Front Panel Signal Connections Connector Description Function IF IN SMA connector Analog input connection digitizes data and triggers acq...

Page 7: ...ices If the device is still not listed power off the system ensure the device is correctly installed and restart 4 Record the device identifier MAX assigns to the hardware Use this identifier when pro...

Page 8: ...COPE The NI SCOPE API configures and operates the device hardware and provides customizable acquisition control analysis and measurement options using LabVIEW VIs or LabWindows CVI functions C or LabW...

Page 9: ...rent chassis slot 5 Power on the chassis 6 Verify that the device appears in MAX 7 Reset the device in MAX and perform a self test Related Information Installing the NI 5622 on page 4 What Should I Do...

Page 10: ...dule in a different slot 5 Power on the chassis 6 Perform the self test again Thermal Shutdown Error If you receive an over temperature or thermal shutdown error and your device shuts down complete th...

Page 11: ...Help Worldwide Support and Services The National Instruments website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and applicati...

Page 12: ...mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your softwa...

Reviews: