background image

Store the device in the antistatic package when the device is not in use.

PXIe-5764 Kit Contents

The following items are included in the device kit:

The PXIe-5764

The FlexRIO Support driver software media

Documentation:

Maintain Forced-Air Cooling Note to Users

PXIe-5764 Getting Started Guide

 (this document)

Preparing the Environment

Ensure the environment in which you are using the PXIe-5764 meets the following

specifications.

Operating environment

Ambient temperature range

0 °C to 45 °C (Tested in accordance with

IEC-60068-2-1 and IEC-60068-2-2. Meets

MIL-PRF-28800F Class 3 low temperature

limit and MIL-PRF-28800F Class 4 high

temperature limit.)

Relative humidity range

10% to 90%, noncondensing (Tested in

accordance with IEC 60068-2-56.)

Maximum altitude

2,000 m (800 mbar) (at 25 °C ambient

temperature)

Pollution Degree

2

Indoor use only.

Note

 

For complete specifications, refer to the specifications document for your

device at 

ni.com/manuals

.

Installing the Application Software and Driver

Before installing your hardware, you must install the application software and instrument

driver. Visit 

NI FlexRIO Driver Supported Versions for FlexRIO Adapters and Modules

 to

determine which minimum software versions you need for your device. Install the software in

the following order:
1. Install LabVIEW.

4

  | 

ni.com

  | 

PXIe-5764 Getting Started Guide

Summary of Contents for PXIe-5764

Page 1: ...PXIe 5764...

Page 2: ...t documentation where this symbol is marked Contents Safety Guidelines 2 Electromagnetic Compatibility Guidelines 2 FlexRIO Documentation and Resources 2 Verifying the System Requirements 3 Unpacking...

Page 3: ...as To minimize interference with radio and television reception and prevent unacceptable performance degradation install and use this product in strict accordance with the instructions in the product...

Page 4: ...System Requirements To use the PXIe 5764 your system must meet certain requirements For more information about minimum system requirements recommended system and supported application development env...

Page 5: ...F Class 3 low temperature limit and MIL PRF 28800F Class 4 high temperature limit Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Maximum altitude 2 000 m 800 m...

Page 6: ...ing Start All Programs National Instruments NI FlexRIO Installing the PXIe 5764 Notice To prevent damage to the PXIe 5764 caused by ESD or contamination handle the module using the edges or the metal...

Page 7: ...ule in place by pulling up on the ejector handle 10 Secure the module front panel to the chassis using the front panel mounting screws Note Tightening the top and bottom mounting screws increases mech...

Page 8: ...ont Panel PXIe 5764 FlexRIO Digitizer DIO 16 Bit 1GS s 4 Vpp MAX AI 0 AI 1 AI 2 AI 3 REF CLK IN The following table describes the signal connections for the PXIe 5764 PXIe 5764 Getting Started Guide N...

Page 9: ...owered on To avoid permanent damage to the PXIe 5764 do not apply a signal to the device when the module is powered down Notice Connections that exceed any of the maximum ratings of any connector on t...

Page 10: ...ples FlexRIO examples are available in LabVIEW s NI Example Finder Complete the following steps to access the examples by task 1 In LabVIEW click Help Find Examples 2 In the NI Example Finder window t...

Page 11: ...m of the carrier portion of the PXIe 5764 KU040 and KU060 FPGA versions Figure 5 Carrier Block Diagram KU040 and KU060 DIO Connector Front Panel Adapter Module Connector 5 V 1 8 V 12 V GPIO Configurat...

Page 12: ...ctual Property CLIP The LabVIEW FPGA Module includes component level intellectual property CLIP for HDL IP integration FlexRIO devices support two types of CLIP user defined and socketed User defined...

Page 13: ...What Should I Do if the PXIe 5764 Doesn t Appear in MAX 1 In the MAX configuration tree expand Devices and Interfaces 2 Expand the Chassis tree to see the list of installed hardware and press F5 to re...

Page 14: ...ts through ni com the application development environment ADE for your application This item is also installed with the driver software Support ni com support Located at ni com manuals FlexRIO ni com...

Page 15: ...ovide up to date contact information support phone numbers email addresses and current events Information is subject to change without notice Refer to the NI Trademarks and Logo Guidelines at ni com t...

Reviews: