Connector
Description
Function
AO 0:1
Standard SMA female
connector
Analog output connection.
REF/CLK IN Standard SMA female
connector
Input for an external Reference Clock or
Sample Clock.
The following table lists the available pins on the DIO connector.
Signal
Type
Direction
MGT Tx± <3..0>
2
Xilinx UltraScale GTH
Output
MGT Rx± <3..0>
2
Xilinx UltraScale GTH
Input
DIO <7..0>
Single-ended
Bidirectional
5.0 V
DC
Output
GND
Ground
—
Notice
The maximum input signal levels are valid only when the module is
powered on. To avoid permanent damage to the PXIe-5785, do not apply a signal to
the device when the module is powered down.
Notice
Connections that exceed any of the maximum ratings of any connector on
the PXIe-5785 can damage the device and the chassis. NI is not liable for any
damage resulting from such connections.
Configuring the PXIe-5785 in MAX
Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX
informs other programs about which NI hardware products are in the system and how they are
configured. MAX is automatically installed with FlexRIO.
1.
Launch MAX.
2.
In the configuration tree, expand
Devices and Interfaces
to see the list of installed NI
hardware.
Installed modules appear under the name of their associated chassis.
3.
Expand your
Chassis
tree item.
2
MGTs are available only on devices with KU040 and KU060 FPGAs.
8
|
ni.com
|
PXIe-5785 Getting Started Guide