background image

Where to Go Next

more about your products through ni.com. 

*This item is also installed with the driver software.

DISCOVER

Services
ni.com/services

NI Community
ni.com/community

Support
ni.com/support

PROGRAM

Located online at ni.com/manuals

Located using the NI Example Finder

Digital Pattern Help* 

NI-Digital Pattern 
 Examples* 

NI-Digital Pattern 
Driver 

 DEVELOP

 

+

 

DEBUG

EXPLORE

PXIe-6570 Specifications* 

Getting Started  
with LabVIEW  

Develop pin and channel
map files, specifications
files, pin levels, time sets,
and pattern files using the  
Digital Pattern Editor.

Debug with pin view pane,
History RAM results,  
Shmoo plots, and  
digital scope.

the Digital Pattern Editor, 

application development  

environment (ADE)

 and instrument specifications.

patterns and configuration files 

for the digital pattern instrument.

custom applications with

NI-Digital Pattern Driver 

LabVIEW or .NET API.

Digital Instruments
ni.com/digital-instruments

National Instruments 
.NET Support  

Digital Pattern Help*

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

PXIe-6570 Getting Started Guide

  | 

© National Instruments

  | 

15

Summary of Contents for PXIe-6570

Page 1: ...quirements 2 Unpacking the Kit 2 Kit Contents 3 Preparing the Environment 3 Installing the Software 3 Digital Pattern Editor 4 NI Digital Pattern Driver 4 Associated Drivers 5 Installing the PXIe 6570...

Page 2: ...ielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input output ports and connected to the product using a shielded cable If unshielded...

Page 3: ...ver and Digital Pattern Editor media NI part number 785249 03 separately Preparing the Environment Ensure that the environment in which you are using the PXIe 6570 meets the following specifications O...

Page 4: ...tate of the digital pattern instrument The Digital Pattern Editor is installed when you install NI Digital Pattern Driver For more information refer to the Digital Pattern Help To access Digital Patte...

Page 5: ...g the PXIe 6674T with digital pattern instruments refer to the Digital Pattern Help Visit ni com downloads to download NI Sync Installing the PXIe 6570 Caution To prevent damage to the PXIe 6570 cause...

Page 6: ...ure 2 PXIe 6570 Installation 4 3 2 1 1 PXI Express Chassis 2 Ejector Handle in Down Position 3 NI PXI Express Two Slot Module 4 Captive Screw 8 Secure the module front panel to the chassis using the f...

Page 7: ...68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 GND CAL FORCE GND DIO 0 CAL GND DGS DIO 2 GND DIO 4 RESERVED DIO 6 GND DIO 8 GND DIO 10 GND DIO 1...

Page 8: ...und Optional DGS for improved accuracy at higher currents in some configurations CAL GND Analog Resource for external calibration 67 CAL FORCE Analog Resource for external calibration 30 60 RESERVED N...

Page 9: ...il the instrument is reset or calibration succeeds The instrument has detected an unlocked condition on a PLL that might result in incorrect data To clear this error condition reset the instrument pro...

Page 10: ...operly designed and shielded input output ports and connected to the product using a shielded cable If unshielded cables or accessories are not properly installed and shielded the EMC specifications f...

Page 11: ...ier MAX assigns to the hardware Use this identifier when programming the PXIe 6570 5 Self test the hardware by selecting the item in the configuration tree and clicking Self Test in the MAX toolbar Th...

Page 12: ...tions using the PXIe 6570 Digital Pattern Instrument Examples To locate programming and operating examples refer to the following table Table 6 NI Digital Pattern Driver Example Locations Application...

Page 13: ...nterfaces 2 Expand the Chassis tree to see the list of installed hardware and press F5 to refresh the list 3 If the module is still not listed power off the system ensure that all hardware is correctl...

Page 14: ...is powered on Applying external signals while the module is powered off may cause damage Disconnect any signals from the PXI Express module front panels 2 Remove any front panel connections from the...

Page 15: ...ments National Instruments NET Support Digital Pattern Help Worldwide Support and Services The NI website is your complete resource for technical support At ni com support you have access to everythin...

Page 16: ...oducts technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find informatio...

Reviews: