background image

Caution

 

This icon denotes a caution, which advises you of precautions to take to

avoid injury, data loss, or a system crash.

Caution

 

The protection the PXIe-8238 provides can be impaired if it is used in a

manner not described in the user documentation.

Caution

 

To ensure the specified EMC performance, operate this product only with

shielded cables and accessories.

Related Documentation

The following documents contain information that you might find helpful as you read this
manual:

Your chassis documentation

PXI Express Hardware Specification

, Revision 2.0

PXI-6 PXI Express Software Specification

PICMG CompactPCI Express EXP.0 R1.0 Specification

PCI Express Base Specification

, Revision 2.1, PCI Special Interest Group

PXI Express Features

Benefits of PXI Express

The PXI (PCI eXtensions for Instrumentation) industry standard, an open specification
governed by the PXI Systems Alliance (PXISA), has quickly gained adoption and grown in
prevalence in test, measurement, and control systems since its release in 1998. One of the key
elements driving the rapid adoption of PXI is its use of PCI in the communication backplane.
As the commercial PC industry has improved the available bus bandwidth by evolving PCI to
PCI Express, PXI is now able to meet even more application needs by integrating PCI Express
into the PXI standard. By taking advantage of PCI Express technology in the backplane, PXI
Express increases the available PXI bandwidth from up to 132 MB/s to up to 8 GB/s for a
more than 60x improvement in bandwidth.

PXI Express maximizes both hardware and software compatibility with PXI modules. PXI
Express hybrid slots deliver both PCI and PCI Express signaling to accept devices that use
PXI communication and triggering or the newer PXI Express standard. Software compatibility
is maintained because PCI Express uses the same OS and driver model as PCI, resulting in
complete software compatibility among PCI-based systems, for example PXI, and PCI
Express-based systems such as PXI Express.

PXI Express, like PXI, leverages from the CompactPCI specification to define a rugged,
modular form factor that offers superior mechanical integrity and easy installation and removal
of hardware components. PXI Express products offer higher and more carefully defined levels
of environmental performance required by the shock, vibration, temperature, and humidity
extremes of industrial environments. Mandatory environmental testing and active cooling is

2

  | 

ni.com

  | 

PXIe-8238 User Manual

Summary of Contents for PXIe-8238

Page 1: ...limits for electromagnetic compatibility EMC stated in the product specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated...

Page 2: ...C industry has improved the available bus bandwidth by evolving PCI to PCI Express PXI is now able to meet even more application needs by integrating PCI Express into the PXI standard By taking advant...

Page 3: ...ch to a PXI Express system via a high bandwidth low latency PXI Express backplane Gen2 x8 link With the 10Gb Ethernet it allows offloading data from a PXI Express system to an external storage solutio...

Page 4: ...ing user interfaces a complete ANSI C environment for building your test program logic and a collection of automated code generation tools as well as utilities for building automated test systems moni...

Page 5: ...x and support for more than two hundred devices on Linux with the NI DAQmx driver you now can create Virtual Instruments based on the Linux OS The NI VISA driver for Linux has improved instrument cont...

Page 6: ...6 02 mm 2 645 in 67 17 mm 2 296 in 58 32 mm 1 948 in 49 47 mm 0 000 in 0 00 mm 0 249 in 6 33 mm 0 612 in 15 54 mm NI PXIe 8238 ETH 0 LINK ACT LINK ACT SPEED SPEED ETH 1 Electrical Power Rail Typical V...

Page 7: ...tal Operating Environment Ambient temperature range 0 C to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 6...

Page 8: ...of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 1 IEC 61326 1 Class A emissions Basic immunity EN 55011 CISPR 11 Group 1 Class A emissions E...

Page 9: ...ize Our Environmental Impact web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not includ...

Page 10: ...TD VeeT VeeR RS1 Rx_LOS RSO MOD_ABS SCL Tx_Disable SDA Tx_Fault VeeT 10 9 8 7 6 5 4 3 2 20 1 11 12 13 14 15 16 17 18 19 Table 1 SFP Connector Signals Pin Symbol Name Description 1 VeeT Module Transmit...

Page 11: ...Receiver Ground 15 VccR Module Receiver 3 3 V Supply 16 VccT Module Transmitter 3 3 V Supply 17 VeeT Module Transmitter Ground 18 TD Transmitter Non Inverted Data Input 19 TD Transmitter Inverted Dat...

Page 12: ...hone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers em...